Owner manual

Turbine Flow Meter, 1100 Series
TURBINE REPLACEMENT
The Model 1100 turbine flow meter uses wear resistant moving parts to provide trouble-free operation and long service life.
The Designed for easy field service of a damaged flow meter Model 1100 repair kits replace only the internal parts, rather than
replacing the entire flow meter. Repair parts use stainless steel alloys and tungsten carbide construction materials.
Each repair kit is factory calibrated to ensure accuracy throughout the entire flow range. Each kit is complete and includes
a new K factor, which is the calibrated number of pulses generated by each gallon of liquid. Recalibration of the monitor or
other electronics uses the K factor to provide accurate output data.
OTE:N If the meter repair kit part number ends in NCC (no calibration), it was not factory calibrated. For these repair kits, use
the nominal K factor.
Turbine Replacement Kit Part Number
Flow Meter Size
Replacement Kit Fits
Meter Part Number
Repair Kit Part Number
3/8 in. B110-375, B110-375-1/2 B251-102
1/2 in. B110-500, B110-500-1/2 B251-105
3/4 in. B110-750, B110-750-1/2 B251-108
7/8 in. B110-875 B251-109
1 in. B111-110 B251-112
1-1/2 in. B111-115 B251-116
2 in. Low B111-121 B251-116
2 in. B111-120 B251-120
3 in. B111-130 B251-131
4 in. B111-140 B251-141
6 in. B111-160 B251-161
8 in. B111-180 B251-181
10 in. B111-200 B251-200
Standard Magnetic Pick-up All Meter Sizes B111109
Table 2: Repair kit part numbers
Turbine Assembly Removal
HIGH-PRESSURE LEAKS ARE DANGEROUS AND MAY CAUSE PERSONAL INJURY. MAKE SURE TO SHUT OFF FLUID FLOW
AND RELEASE RESIDUAL PRESSURE IN THE LINE BEFORE ATTEMPTING TO REMOVE THE METER.
AVERTISSEMENT
LES FUITES À HAUTE PRESSION SONT DANGEREUSES ET PEUVENT CAUSER LE DOMMAGE CORPOREL. ASSUREZ-VOUS
QUE LE FLUX DE FLUIDE A ÉTÉ COUPÉ ET DE LA PRESSION DANS LA LIGNE A ÉTÉ LIBÉRÉE AVANT D’ESSAYER D’ENLEVER
LE MÈTRE.
Page 8 July 2014