Owner manual
Turbine Flow Meter, 1100 Series
New Turbine Kit Installation
MPORTANTI
Before reassembly, note that an arrow is cast or engraved on each component. The arrow indicates the primary flow direction. When
reassembled, the arrowheads must point in the direction of the fluid flow. The arrows must also be oriented in the up position on
both rotor supports. The magnetic pickup side of the body signifies the up position. Performance of repair kit calibration is in the up
position. Reinstallation of the repair kit in the up position ensures continuation of accurate measurements. Figure 7, Figure 8, and
Figure 9 show the proper alignment and orientation of the repair kits.
OTE:N Fractional size (3/8 in., 1/2 in. and 3/4 in.) rotors do not contain a cast or engraved arrow. However, a colored cap
on the downstream side of the rotor shaft indicates flow direction. Remove this cap before assembly, noting
flow direction.
1. Install one of the rotor supports into the body bore, noting the orientation of the arrow.
2. Secure a retaining ring in the groove provided. Check for complete installation of retaining rings in each groove.
OTE:N 4 in. and larger meters have a retaining ring at both ends of the rotor (see Figure 9).
3. Insert the rotor and second rotor support in the opposite side of the body, noting the orientation of the arrow.
4. Secure the second retaining ring in the opposite groove, using the same procedure as in step 2 above.
EXCESS AIR PRESSURE MAY DAMAGE THE ROTOR AND BEARINGS BY OVER SPINNING.
ATTENTION
LA PRESSION ATMOSPHÉRIQUE EXCESSIVE PEUT ENDOMMAGER LE ROTOR ET LES ROULEMENTS PRÈS AU-DESSUS DE
LA ROTATION.
5. Check the meter by lightly pung air through the assembly. If the rotor does not turn freely, disassemble the meter and
remove anything that might obstruct movement of the rotor.
OTE:N At this time, electronics require recalibration. Refer to the display's user manual. If there are any questions on
recalibration, contact Badger Meter, Inc. or the manufacturer of the associated electronics.
6. Install the magnetic pickup.
PART NUMBER INFORMATION
Part Number Meter Size
End to End Length
End Connection
Flow Ranges
inches mm gpm bpd m³/d
B110-375-1/2 3/8 in. 3 76.2 1/2 in. Male NPT 0.6…3.0 20…100 3.3…16
B110-500-1/2 1/2 in. 3 76.2 1/2 in. Male NPT 0.75…7.5 25…250 4.1…41
B110-750-1/2 3/4 in. 3 76.2 1/2 in. Male NPT 2…15 68…515 10.9…81.75
B110-375 3/8 in. 4 101.6 1 in. Male NPT 0.6…3.0 20…100 3.3…16
B110-500 1/2 in. 4 101.6 1 in. Male NPT 0.75…7.5 25…250 4.1…41
B110-750 3/4 in. 4 101.6 1 in. Male NPT 2…15 68…515 10.9…81.75
B110-875 7/8 in. 4 101.6 1 in. Male NPT 3…30 100…1000 16…160
B111-110 1 in. 4 101.6 1 in. Male NPT 5…50 170…1700 27.25…272.5
B111-115 1-1/2 in. 6 152.4 1-1/2 in. Male NPT 15…180 515…6000 82…981
B111-121 2 in. Low 6 152.4 2 in. Male NPT 15…180 515…6000 82…981
B111-120 2 in. 10 254 2 in. Female NPT 40…400 1300…13,000 218…2180
B111-130
3 in. 12-1/2 317.5 3 in. Grooved End 60…600 2100…21,000 327…3270
B111-140 4 in. 12 304.8 4 in. Grooved End 100…1200 3400…41,000 545…6540
B111-160 6 in. 12 304.8 6 in. Grooved End 200…2500 6800…86,000 1090…13,626
B111-180 8 in. 12 304.8 8 in. Grooved End 350…3500
12,000…120,000
1363…19,076
B111-200 10 in. 12 304.8 10 in. Grooved End 500…5000
17,000…171,000
2725…27,252
Page 10 July 2014