Datasheet

2
Measurement: (mm)
Technical characteristics:
Protection index
:
IP 66 and IP69K following IEC 60529
NEMA 4x,12,13
IP 20 at the back of panel following IEC 60529
Protection against mechanical impact:
IK 05 following IEC 62262
Operating voltage :
24 V AC/DC (+/- 10%)
130 V AC/DC* (+/- 10%)
230 V AC/DC* (+/- 10%)
*Declarative rating
Terminals :
Screw terminals
Tightening torque for terminals :
. Recommended 1.2N.m.
Consumption :
. 24V : 4.6mA
. 130V : 5.2mA
. 230V : 4.6mA
Insulation voltage :
300 V
Pollution degree :
3
Tightening torque for locking ring :
Recommended 3 N.m. or tightened with fixing tool to
hand tight after pressure point plus another half turn
Electrical insulation :
. Classe II according to IEC 60947-5-1
Operating temperature :
. minimum : -25°C maximum : +70°C
Storage Temperature :
. minimum : -40°C maximum : +70°C
Cold test :
. according to IEC 60068-2-1
Dry heat test :
. according to IEC 60068-2-2
Constant humidity test :
. according to IEC 60068-2-3
Materials:
Polycarbonate (Lens)
Polyamide 66 , fiber glass loaded (body)
Certifications and conformity:
CB test (IEC 60947-5-1); CE; CCC; UL (USA and
Canada) and BV
Compliant with RoHs and Reach
Packaging:
Minimum Order Quantity=10
Guarantee:
10 years guarantee