 . AC15 (Alternating current) 
 - Ue = 60 V  Ie = 10 A 
 - Ue = 110 V Ie = 6 A 
 - Ue = 220 V Ie = 3 A 
 - Ue = 380 V Ie = 2 A 
 - Ue = 500 V Ie = 1,5 A 
 - Ue = 600 V Ie = 1,2 A 
 . DC13 (Direct current) 
 - Ue = 24 V  Ie = 2,5 A 
 - Ue = 48 V  Ie = 1,4 A 
 - Ue = 60 V  Ie = 1 A 
 - Ue = 110 V Ie = 0,55 A 
 - Ue = 220 V Ie = 0,27 A 
 - Ue = 300 V Ie = 0,2 A 
Conventional thermal current in enclosure
Conventional thermal current in enclosureConventional thermal current in enclosure
Conventional thermal current in enclosure 
 :
::
: 
 . For standards blocks (screw or Plug-in terminals) 
 . Ith = 16 A in AC 
 . Ith = 2,5 A in DC 
 . For Faston terminals blocks 
 . Ith = 10 A in AC 
 . Ith = 2,5 A in DC 
 . For Pin style terminal blocks 
 . Ith = 5 A in AC 
 . Ith = 1 A in DC 
Rated insulation voltage
Rated insulation voltageRated insulation voltage
Rated insulation voltage 
 :
::
: 
 . For screw terminal contact blocks 
 . Ui = 690 V according to IEC 60947-5-1 
 . Ui = 600 V according to UL508 
 . For faston terminal blocks 
 . Ui = 320 V according to IEC 60947-5-1 
 . Ui = 300 V according to UL 508 
 . For LED blocks 
 . Ui = 300 V according to IEC 60947-5-1 
 . For Pin-style terminal blocks 
 . Ui = 250 V according to IEC 60947-5-1 
Pollution degree
Pollution degreePollution degree
Pollution degree 
 :
::
: 
 . 3 
Rated impulse withstanding voltage 
Rated impulse withstanding voltage Rated impulse withstanding voltage 
Rated impulse withstanding voltage  
 :
::
: 
 . For standard contact and faston blocks 
 . Uimp = 6kV according to IEC 60947-5-1 
 . For LED and Pin-style terminal blocks 
 . Uimp = 4kV according to IEC 60947-5-1 
L
LL
LED 
ED ED 
ED blocks
blocksblocks
blocks 
 :
::
: 
 . Life time: 
 - red and yellow  100 000 hours at 25°C under Un 
 - others colours  50 000 hours at 25°C under Un 
 . LED power consumption: 
 . For 24 V = 20 mA 
 . For 48 V = 15 mA 
 . For 130 V = 20 mA 
 . For 230 V = 16 mA 
5
55
5. 
. . 
. TECHNIC
TECHNICTECHNIC
TECHNICAL CHARACTERISTICS
AL CHARACTERISTICSAL CHARACTERISTICS
AL CHARACTERISTICS 
 . Operating voltage : 12, 24, 48, 130, 230 V 
 . Frequency: 50 or 60 Hz 
 . Electromagnetic compatibility : 
 . Electrostatic discharge immunity test according test IEC 
61000-4-2 level 2 
 . Radiated, radio-frequency, electromagnetic field immunity test 
according to IEC 61000-4-3 level 3 
 . Electrical fast transient/burst immunity test according to IEC 
61000-4-4 : 
 . Level 2 for Un = 24 to 48 V 
 . Level 3 for Un = 110 to 230 V 
 . Surge immunity test 1,2 / 50 μs according to IEC 61000-4-5 : 
 . Level 2 for Un = 24 to 48 V 
 . Level 3 for Un = 110 to 230 V 
 . Immunity to conducted disturbances, induced by radio-
frequency fields according to IEC 61000-4-6 
 . Voltage dips, short interruptions and voltage variation immunity 
tests according to IEC 61000-4-11 only on models Un = 100 to 
230V 
Protection Fuse
Protection FuseProtection Fuse
Protection Fuse 
 :
::
: 
 . For the standards blocks 
 . 10 A gG according to IEC 60947-5-1 
 . For pin-style terminals blocks 
 . 6 A gG according to IEC 60947-5-1 
Mechanical life
Mechanical lifeMechanical life
Mechanical life 
 :
::
: 
 . For screw, Faston and pin-style terminals blocks 
 . 5 000 000 cycles 
Electrical operating life
Electrical operating lifeElectrical operating life
Electrical operating life 
 :
::
: 
 . For screw, faston and pin-style terminal blocks 
 . 1 000 000 cycles: 
 - AC15 – B300 
 . Ue = 120 V Ie = 3 A 
 . Ue = 240 V Ie = 1,5 A 
 - DC13 – R300 
 . Ue = 125 V Ie = 0,22 A 
 . Ue = 250 V Ie = 0,1 A 
Operating Temperature
Operating TemperatureOperating Temperature
Operating Temperature 
 :
::
: 
 . minimum : -25°C maximum : +70°C 