Datasheet
7 / 9 
R
RR
Re
ee
ef
ff
fe
ee
erence(s)
rence(s)rence(s)
rence(s) 
 : 
: : 
: See 
See See 
See range
rangerange
range sec
 sec sec
 section
tiontion
tion
4. 
4. 4. 
4. INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION 
Control station mounting
Control station mountingControl station mounting
Control station mounting 
 :
::
: 
. use base mounting contact blocks 
Printed circuit board mounting
Printed circuit board mountingPrinted circuit board mounting
Printed circuit board mounting 
 :
::
: 
 . use Pin-style contact blocks 
Current 
Current Current 
Current s
ss
supply
upplyupply
upply 
 :
::
: 
 . On the back side of the block 
Visualization of the contact state
Visualization of the contact stateVisualization of the contact state
Visualization of the contact state:
::
: 
 . Contact state is visible on the back side of the contact block, 
mounted block (colour plunger, visible) 
Type
TypeType
Type of
 of of
 of wire
 wire wire
 wire 
 :
::
: 
 For screw terminal contact blocks (front mounting or base 
mounting): 
 . Solid or stranded wire without ferrule : 2x 0,5 mm² to 2x 2,5 
mm² 
 . Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm² 
 For plug-in terminal contact blocks: 
 . Solid or stranded wire without ferrule : 2x 0,5 mm² to 2x 2,5 
mm² 
 . Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm² 
 For Faston terminal contact blocks : 
 . 1 faston clip 6,35 mm or 2 faston clips 2,85 mm 
 For pin style terminal contact blocks : 
 . Ø 1 mm 
Connection with screw and plug
Connection with screw and plugConnection with screw and plug
Connection with screw and plug-
--
-in terminals
in terminalsin terminals
in terminals 
 :
::
: 
 . Terminals protected against direct contact (IP2X) 
 . Recommended terminal torque: 1.2 Nm 
4. 
4. 4. 
4. CONNECTION
CONNECTIONCONNECTION
CONNECTION
Tools
ToolsTools
Tools 
 :
::
: 
 . For plug-in terminals, it is advisable to use screwdriver with Flat 
blade - 2.5 mm 
 . For screw terminals, it is advisable to use screwdriver Phillips 
n°2 or screwdriver with flat blade - 5,5 mm 
 . To remove the block it is advisable to use a flat blade 
screwdriver 
Connecti
ConnectiConnecti
Connecting
ngng
ng blocks on clips
 blocks on clips blocks on clips
 blocks on clips 
 :
::
: 
    Clip 
    single  3 
positions 
5 
positions 
1 level  X  X  X 
Blocks 
2 levels    X   
6 and more NO blocks on a 3 position clip are unsuitable with 
EN418 push and turn mushroom head. 
5. 
5. 5. 
5. TECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICSTECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS 
Maximum operating current
Maximum operating currentMaximum operating current
Maximum operating current:
::
: 
 . For standards blocks (screw or Plug-in terminals) 
 . AC15 (Alternating current) 
 - Ue = 120 V Ie = 8 A 
 - Ue = 230 V Ie = 6 A 
 - Ue = 400 V Ie = 4,5 A 
 - Ue = 440 V Ie = 3,5 A 
 - Ue = 500 V Ie = 2,5 A 
 - Ue = 690 V Ie = 1 A 
 . DC13 (Direct current) 
 - Ue = 24 V  Ie = 1,5 A 
 - Ue = 48 V  Ie = 1 A 
 - Ue = 60 V  Ie = 0,7 A 
 - Ue = 110 V Ie = 0,3 A 
 - Ue = 230 V Ie = 0,2 A 
 . For Pin style terminals blocks 
 . AC15 (Alternating current) 
 - Ue = 120 V Ie = 8 A 
 - Ue = 240 V Ie = 6 A 
 - Ue = 400 V Ie = 4 A 
 . DC13 (Direct current) 
 - Ue = 125 V Ie = 0,22 A 
 - Ue = 250 V Ie = 0,1 A 
 . For Faston terminal blocks 
 . AC15 (Alternating current) 
 - Ue = 120 V Ie = 6 A 
 - Ue = 240 V Ie = 3 A 
 . DC13 (Direct current) 
 - Ue = 125 V Ie = 0,55 A 
 - Ue = 250 V Ie = 0,27 A 
  Creation date: 22/10/07  Update : 22/10/07 