Specifications

NEW!
809
NETWORK & WIRELESS
NETWORK & WIRELESS
13
WE MAKE IT EASY.
kele.com 888-397-5353 USA
BAPI WIRELESS SYSTEM OUTPUT MODULES
BA/COM, BA/ROM, BA/RYOM, BA/RYOL, BA/SOM, BA/VOM
SG
PG
Comm
SG
PG
Comm
Service
Button
Power Bus
Not Required
Loop Voltage
9 to 36 VDC
Current
+ Output --
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power Bus*
9 to 36 VDC
17 to 31 VAC
Votage
+ Output --
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power Bus*
9 to 36 VDC
17 to 31 VAC
Relative
Output
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power Bus*
9 to 36 VDC
17 to 31 VAC
Switched
Output
www.buplhvac.com
www.buplhvac.com
Power Bus*
9 to 36 VDC
17 to 31 VAC
SG
PG
Comm
418 MHz
Activator
*17-30 VAC
Power
To Controller
Thermistor
Input
24 VDC
Signal
To Controller
O-5 VDC or
O-10 VDC
To Controller
To Controller
Device
(Typically A Relay)
Typically Hard Wired
or Interlocked On Rail
Typically Service Button to
Program Output Modules
To RF Transmitters
Typical BA/RCV
RF Receiver
With RS485
Communication
BA/R YOM
Digital Output
N.O. or N.C.
BA/ROM
T
hirmistor Simulat
0K type 2 @ 77°F
or 10K type 3 @ 77°F
BA/VOM
O-5 VDC Output
or
O-10 VDC Output
BA/COM
4-20 MA Output
SG
PG
Comm
SG
PG
Comm
Service
Button
Power bus
not required
Loop voltage
9 to 36 VDC
Current
+ output --
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power bus*
9 to 36 VDC
17 to 31 VAC
Votage
+ output --
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power bus*
9 to 36 VDC
17 to 31 VAC
Relative
output
www.buplhvac.com
SG
PG
Comm
SG
PG
Comm
Service
Button
Power bus*
9 to 36 VDC
17 to 31 VAC
Switched
output
www.buplhvac.com
www.bapihvac.com
Power bus*
9 to 36 VDC
17 to 31 VAC
SG
PG
Comm
418 MHz
Antenna
*17-30 VAC
Power
To controller
thermistor
input
9 to 36 VDC
Current cignal
to controller
0-5 VDC or
0-10 VDC
To controller
To controller
device
(typically a relay)
(17–30 VAC or 9–30 VDC)
Interlocking wiring plugs with
screw terminals, hard wire or
snap together on DIN rail
Service button, used
to assign output
modules to transmitters
Typical BA/EZ-RCV
RF receiver
with RS485
communication
BA/EZ-RYOM
Digital output
N.O. or N.C.
BA/EZ-ROM
Thermistor simulator
10 k
type 2 @ 77°F
or 10 k
type 3 @ 77°F
BA/EZ-VOM
0-5 VDC output
or
0-10 VDC output
BA/EZ-COM
4-20 mA output
*The power bus maybe split when needed and is required when module current draw exceeds the
system power supply. If the power bus is split re-established with an indendently power source.
Do not parallel power sources.
*The power bus may be split when needed and is required when module current draw exceeds the
system power supply. If the power bus is split, re-establish with an independent power source.
Do not parallel power sources.
WIRING
ORDERING INFORMATION
RELATED PRODUCTS
BA/AOM-CONN Pluggable terminal block kit
VC350-12 Power supply 24 VAC to 12 VDC, 350 mA
MODEL DESCRIPTION
BA/COM-C-EZ BAPI wireless current output module, 4-20 mA = 50°F to 90°F
BA/COM-E-EZ BAPI wireless current output module, 4-20 mA = 60°F to 80°F
BA/COM-H-EZ BAPI wireless current output module, 4-20 mA = -20°F to 120°F
BA/COM-M-EZ BAPI wireless current output module, 4-20 mA = 0 to 100% RH
BA/ROM-102-EZ BAPI wireless thermistor simulation output module, 10K type 24 (35°F to 120°F )
BA/ROM-103-EZ BAPI wireless thermistor simulation output module, 10K type 3 (32°F to 120°F )
BA/RYOM-NC-EZ Relay output momentary, normally open output
BA/RYOM-NO-EZ Relay output momentary, normally closed output
BA/SOM-10-EZ BAPI wireless setpoint output module, 0 to 10 VDC
BA/SOM-60-EZ BAPI wireless setpoint output module, 0 to 10K
BA/SOM-80-EZ 0 to 20K output
BA/SOM-84-EZ 10 to 30K output
BA/SOM-102-C-EZ 10 k-2 thermistor, 50°F to 90°F
BA/VOM-10-C-EZ BAPI wireless voltage output module, 0-10 VDC = 50°F to 90°F
BA/VOM-10-E-EZ BAPI wireless voltage output module, 0-10 VDC = 60°F to 80°F
BA/VOM-10-H-EZ BAPI wireless voltage output module, 0-10 VDC = -20°F to 120°F
BA/VOM-10-M-EZ BAPI wireless voltage output module, 0-10 VDC = 0 to 100% RH
BA/RYOL-NC-EZ Relay output latching, normally closed default
BA/RYOL-NO-EZ Relay output latching, normally open default