Specifications

NEW!
775
NETWORK & WIRELESS
NETWORK & WIRELESS
13
WE MAKE IT EASY.
kele.com 888-397-5353 USA
Refer to the configuration setup instruction manual for configuration of the MOD9200BNT registers and BACnet variables setup.
A PC is required for the setup of the Transceiver.
Refer to the configuration setup instruction manual for configuration of the MOD9200LON registers and SNVT variables setup.
A PC is required for the setup of the Transceiver.
Choose a location close to the Gateway network connection and away from the ground.
Mount the gateway on the wall using four #8 screws.
24 VAC Input - Connect 24VAC 60 Hz to the input terminals using 18-20 AWG wire.
MSTP (RS485) - Use 20 or 22 gauge shielded twisted pair wire to connect the Transceiver (Terminals A+ & B-) to the MSTP
network.
FTT-10 (LonWorks) - Use 20 or 22 gauge shielded twisted pair wire to connect the Transceiver (Terminals A+ & B-) to the LON
network. Must be Echelon approved cable.
ORDERING INFORMATION
FRONTIER 2.0 GATEWAY TRANSCEIVERS
MOD9200
INSTALLATION
MODEL DESCRIPTION
MOD9200BNT BACnet MSTP network transceiver
MOD9200D Modbus network transceiver
MOD9200LON-A Up to 30 wireless wall temp sensors with setpoint adjustments and/or push button override switches, up to 6
humidity sensors, up to 50 wireless digital outputs & up to 50 wireless analog out.
MOD9200LON-B Up to 50 wireless temperature only sensors (50 wall, duct or immersion types), up to 50 wireless digital
outputs & up to 50 wireless analog out.
MOD9200LON-C Up to 50 wireless sensors (up to 50 temperature points and up to 50 humidity points), up to 50 wireless digital
outputs & up to 50 wireless analog out.
MOD9200LON-D Up to 50 wireless devices (40 0-10VDC point types, 40 discrete inputs, 10 temperature,10 humidity point
types), up to 50 wireless digital outputs & up to 50 wireless analog out.
MOD9200LON-E Up to 50 wireless sensors/transmitters (26 temperature points, 26 setpoint adjustments, 26 push button
override switches, 12 CO2 PPM inputs, 6 humidity points, 4 digital status inputs), up to 50 wireless digital
outputs & up to 50 wireless analog out.
MOD9200LON-F Up to 50 wireless sensors (up 40 temperature points, up to 20 humidity points & 40 discrete inputs), up to 50
wireless digital outputs & up to 50 wireless analog out.
CAUTION:
Sensors, Repeaters and receivers should NOT be installed in the following areas:
- Inside metal enclosure or panel
- Inside or immediately next to elevator shaft or elevator banks
- In front of or immediately next to large trees or a large body of water
Transmission distance and performance will be drastically reduced.
CAUTION:
Do not use this product in any safety related applications where human life may be affected.
March 2014