Specifications
NEW!
NETWORK & WIRELESS
772
NEW!
NETWORK & WIRELESS
13
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
kele.com888-397-5353 USA
ORDERING INFORMATION
SONNET WIRELESS ROUTER-SENSORS
RF-RR SERIES
DESCRIPTION
The RF-RR Series of SonNet Wireless Routers-Sensors are used
in conjunction with the SonNet RF-RX20 or RF-RX40 receiver units,
and RF-RS series of battery powered wireless sensors, and are used
to route signals from battery powered nodes and other routers to
the receiver module, where the signal strength of a direct path is not
sufficient for reliable communications.
Note: Each router can support a maximum of 16 ‘children’, which can
consist of a maximum of 8 battery powered nodes and 8 routers, or
up to 16 routers if there are no battery powered nodes. Consideration
should be given to network planning for redundancy in case of router
failure or damage. Routers automatically find the best path back to
the receiver, which may be directly to the receiver or via other ‘parent’
routers.
FEATURES
• Proven 802.15.4 low power network
• Complete range of sensor types
• Allows networks to be expanded
• Self-healing tree topology
• Lower installation costs
• Easy to install and commission
MODEL DESCRIPTION
RF-RR-R-622 Duct humidity and temperature sensor/router, 24 VAC
RF-RR-R-631 Wall humidity and temperature sensor/router, 24 VAC
RF-RR-R-632 Outside humidity and temperature sensor/router, 24 VAC
RF-RR-T-322 Duct temperature sensor/router, 150 MM probe, 24 VAC
RF-RR-T-331 Outside air temperature sensor/router, 24 VAC
RF-RR-T-332 Outside air temperature sensor/router, with rad. Sheild, 24 VAC
RF-RR-T-341 Immersion temperature sensor/router, 150 MM probe, 24 VAC
RF-RR-T-351 Clamp-on temperature sensor/router, 24 VAC
RF-RR-T-555-2 Flyind lead temperature sensor/router, 2M, 24 VAC
RF-RR-T-555-5 Flying lead temperature sensor/router, 5M, 24 VAC
RF-RR-1000 Room temperature sensor/router, 24VAC
RF-RR-1000-MS Room temperature sensor/router, 24VAC, override button
RF-RR-1000-SP Room temperature sensor/router, 24VAC, set point
RF-RR-1000-MS-SP Room temperature sensor/router, 24VAC, override button, set point
RF-RR-RH-1000 Room humidity/temperature sensor/router, 24VAC
RF-RR-RH-1000-MS Room humidity/temperature sensor/router, 24VAC, override button
RF-RR-RH-1000-SP Room humidity/temperature sensor/router, 24VAC, set point
RF-RR-RH-1000-MS-SP Room humidity/temperature sensor/router, 24VAC, override button, set point
RF-RR-CO2-1000 Room CO2 sensor/router, 24VAC
RF-RR-CO2-RH-1000 Room CO2/humidity/temperature sensor/router, 24VAC
Supply Voltage 24 VAC / VDC
Transmission Power +10 dBm
Baud Rate 250Kbps
Transmit Frequency 2.4 GHz
Beam Pattern Isotropic
Range 328 ft (100 m)
Communication SonNet
Channels 16
Sensor Accuracy Termperature: ± 0.3°C, RH ± 3%, CO
2
: ± 75
ppm
Operating Temperature -4° to 158°F (-20° to 70°C)
Operating Humidity 90% RH non-condensing
Wiring Terminations 22 AWG
Dimensions
Space Housing 4.53"H x 3.35"W x 1.10"D
(115 x 85 x 28 mm)
Plant Housing 4.57"H x 4.17"W x 2.05"D
(116 x 106 x 52 mm)
Approvals CE, FCC
Weight
RF-RR-R-6xx 0.79 lb (0.36 kg)
RF-RR-T-3xx 0.46 lb (0.21 kg)
RF-RR-T-5xx 0.55 lb (0.25 kg)
RF-RR-1000/CO2/RH 0.26 lb (0.12 kg)
Warranty 3 years
SPECIFICATIONS
March 2014
Plant Housing
Router-Sensor
Space Housing
Router-Sensor
RELATED PRODUCTS PAGE
RF-RX20 Receiver with 20 x 0-10VDC outputs 771
RF-RX40 Receiver with 40 x 0-10VDC outputs 771