Specifications
NEW!
735
NETWORK & WIRELESS
NETWORK & WIRELESS
13
WE MAKE IT EASY.
kele.com 888-397-5353 USA
March 2014
ORDERING INFORMATION
MODEL DESCRIPTION
LT-03 L-Term LON Network Terminator, 1 x TP/FT-10 or TP/LPT-10, 1 x RJ45
LT-13 L-Term LON Network Terminator, 1 x TP/FT-10, 1 x TP/XF-1250
LT-33 L-Term LON Network Terminator, 2 x TP/FT-10 or TP/LPT-10
LT-04 L-Term BACnet and Modbus Network Terminator, 1 x EIA-485, 1 x RJ45
LT-B4 L-Term BACnet and Modbus Network Terminator, 1 x EIA-485 w/ failsafe
LT-04 Modular Plug RJ-45(8P8C)
PinMarking Description
1A + non-inverting pin, B (EIA-485)
2B – inverting pin, A (EIA-485)
3 ... 8NCnot connected
Modbus RTU: LINX-100 Automation Server and terminator LT-B4 with biasing circuit (failsave biasing)
status
LOYTEC
www.loytec.com
Made in Austria
L
L-POW
Power Supply
Input
N
50/60 Hz
85-265VAC
LPOW-2415B
24VDC/15W
+GND
L-Term
Bus Terminator
LOYTEC
www.loytec.com
LT-B4
RS-485
AB
+-
NC
120
5V
510510
NC
24V
AC/DC
GND
LT-B4
L-Term
Bus Terminator
LOYTEC
www.loytec.com
LT-04
RS-485
A
A
B
+-
B
+-
NC
18
LT-04
serial
12-35 VDC INPUT or
12-24 VAC, 40-70 Hz
15 16 174 5 6
~~
+-
DC
AC
statuspower
ACT
LINK
ACT
100Base-T100Base-T
L-INX
Automation Server
Made in EC
1
LOYTEC
www.loytec.com
12 3
2
RS-485RS-485
AB
LINX-100
FT
OPC
CS/RNI
CNIP
AB
EIA-485 A Line (inverting)
-
, DA0
EIA-485 B Line (non-inverting) + , DA1
85−265 VAC
50 / 60 Hz
Modbus Device
RS-485 NETWORK TERMINATOR APPLICATION EXAMPLE
LON NETWORK TERMINATOR APPLICATION EXAMPLE
LON Network Terminator
Application Examples
1)
LT-33 in a typical free topology installation on
tw
o TP/FT-10 channels together with an LS-33CB
2-por
t L-Switch
bus
freecom
TP/FT-10
topology
L-Term
Bus Terminator
LOYTEC
www.loytec.com
TP/FT-10
bus
free
com
topology
LT-33
TP/FT-10
TP/FT-10
2) LT-13 in a typical network with TP/XF-1250
back
bone and free typology on TP/FT-10
together
with two LS-13CB L-Switches
bus
freecom
TP/FT-10
topology
L-Term
Bus Terminator
LOYTEC
www.loytec.com
TP/XF-1250
ABNC
LT-13
bus
freecom
TP/FT-10
topology
L-Term
Bus Terminator
LOYTEC
www.loytec.com
TP/XF-1250
ABNC
LT-13
TP/XF-1250 BackboneTP/XF-1250 Stub
TP/XF-1250 Stub
TP/FT-10
TP/FT-10
serial
12-35 VDC INPUT or
12-24 VAC, 40-70 Hz
15 16 1712 3 4 5 6
~~
+-
DC
AC
ABB
12
A
statuspower
ACTACT
LOYTEC
www.loytec.com
L-switch
EIA709 router
Made in EU
XP
LS-13CB
TP-1250
FT
serial
12-35 VDC INPUT or
12-24 VAC, 40-70 Hz
15 16 1712 3 4 5 6
~~
+-
DC
AC
ABB
12
A
statuspower
ACTACT
LOYTEC
www.loytec.com
L-switch
EIA709 router
Made in EU
XP
LS-13CB
TP-1250
FT
3) LT-03 in a free topology installation together
with a LINX-100 Automation Server
L-Term
Bus Terminator
LOYTEC
www.loytec.com
LT-03
busfree com
topology
bus
freecom
TP/FT-10
topology
18
TP/FT-10
serial
12-35 VDC INPUT or
12-24 VAC, 40-70 Hz
15 16 174 5 6
~~
+-
DC
AC
statuspower
ACT
LINK
ACT
100Base-T100Base-T
L-INX
CS/RNI
Automation Server
Made in EC
1
OPC
LINX-100
LOYTEC
www.loytec.com
CNIP
FT
AB
LT-03 Modular Plug RJ-45(8P8C)
Pin Marking Description
1com tie point
2freefree topology
3 bus bus topology
4 ... 8- not connected
BACNET, LON, MODBUS TERMINATOR
L-TERM SERIES