Specifications

Accessories
M10031B 1413 µS/cm calibration solution,
20 mL sachet (25 pcs)
M10032B 1382 ppm calibration solution,
20 mL sachet (25 pcs)
M10039B 5.00 mS/cm calibration solution,
20 mL sachet (25 pcs)
M10442B 1500 ppm calibration solution,
20 mL sachet (25 pcs)
M100020B Cal-Test solution for SMS315,
20 mL sachet (25 pcs)
M100040B Cal-Test solution for SMS415,
20 mL sachet (25 pcs)
MA811/2 Conductivity probe with 2 m cable
MA812/2 Conductivity probe with 2 m cable
MA815/2 Conductivity probe for SMS315 with
2 m cable
MA816/2 Conductivity probe for SMS415 with
2 m cable
Reliable Conductivity and TDS monitors with Automatic
temperature compensation and 1 point manual calibration
powered by a 12 VDC adapter.
They are ideal for the hydroponic market and allow you to
continuously monitor EC or TDS values directly in your
reservoir.
Other features include: user selectable set point, visual
LED alarm when values go below the set point (for
SMS310 and SMS410).
The CAL test feature on the SMS315 and SMS415 will
warn the user (through a LED) when the probe needs to
be calibrated again!
The monitors are very simple to operate:
1
.
hang your monitor above your reservoir
2. connect the adapter to the meter and plug in the power
supply (make sure that your power supply is in a safe area
from the water!)
3. immerse 2/3 of the probe in the solution
4. the probe can now remain there permanently.
EC/TDS
Ordering Information
SMS310 is supplied complete with 12VDC adapter,
MA811/2 EC probe, 20 mL 1413 µS/cm sachet of calibra-
tion solution, screwdriver for calibration and instruction.
SMS410 is supplied complete with 12VDC adapter,
MA812/2 TDS probe, 20 mL 1382 ppm sachet of calibra-
tion solution, screwdriver for calibration and instruction.
SMS315 is supplied complete with 12VDC adapter,
MA815/2 EC probe, 20 mL 1413 µS/cm sachet of calibra-
tion solution, 20 mL conductivity Cal-Test Solution,
screwdriver for calibration and instruction.
SMS415 is supplied complete with 12VDC adapter,
MA816/2 TDS probe, 20 mL 1382 ppm sachet of calibra-
tion solution, 20 mL conductivity Cal-Test Solution,
screwdriver for calibration and instruction.
Specifications
SMS310 SMS410 SMS315 SMS415
Range EC/TDS 0.0 to 10.0 mS/cm 0 to 1990 ppm 0.00 to 9.99 mS/cm 0 to 1990 mg/L (ppm)
Resolution EC/TDS 0.1 mS/cm 10 ppm 0.01 mS/cm 10 mg/L (ppm)
Accuracy (@25°) ±2% Full Scale ±2% Full Scale ±2% Full Scale ±2% Full Scale
Conversion Factor 0.7 approx. 0.7
Set point 1.5 to 3.5 mS/cm 700 to 1900 ppm
Alarm active when the measure active when the measure
is lower than the set point is lower than the set point
Temperature Compensation automatic, from 5 to 50°C automatic, from 5 to 50°C
Environment 0 to 50°C; max RH 95% 0 to 50°C; max RH 95% 0 to 50°C; max RH 95% 0 to 50°C; max RH 95%
Probe MA811/2 (included) MA812/2 (included) MA815/2 (included) MA816/2 (included)
Power Supply 12 VDC power adapter (included) 12 VDC power adapter (included) 12 VDC power adapter (included) 12 VDC power adapter (included)
Dimensions 165 x 80 x 40 mm 165 x 80 x 40 mm 85 x 104 x 39 mm 85 x 104 x 39 mm
Weight 220 g (meter only) 220 g (meter only) 130 g (meter only) 130 g (meter only)
SMS310/SMS410/SMS315/SMS415
Conductivity and TDS Monitors
27