Specifications
Accessories
MA923D/1 Combination amplified
pH/ORP/Temp probe with DIN
connector and 1 m cable
(will be replaced by SE260)
SE260(*) Combination amplified
pH/ORP/Temp probe with DIN
connector and 1 m cable
M10004B pH 4.01 buffer solution 20 mL
sachet (25 pcs)
M10006B pH 6.86 buffer solution 20 mL
sachet (25 pcs)
M10007B pH 7.01 buffer solution 20 mL
sachet (25 pcs)
M10009B pH 9.18 buffer solution 20 mL
sachet (25 pcs)
M10010B pH 10.01 buffer solution 20 mL
sachet (25 pcs)
MA9004 pH 4.01 buffer solution, 230 mL bottle
MA9007 pH 7.01 buffer solution, 230 mL bottle
MA9015 Electrode storage solution, 230 mL
MA9016 Electrode cleaning solution, 230 mL
M10000B Electrode rinse solution, 20 mL
sachet (25 pcs)
(*) Available from the 1
st
of September 2011
Mi106
Portable pH/ORP/Temp Meter
Hard Carrying Case
Each meter is supplied in a hard carrying case ideal for
field measurements.
Ordering Information
Mi106 is supplied complete with MA923D/1
pH/ORP/Temp amplified probe with 1 meter cable, 20 mL
pH 4.01 and 7.01 sachet of calibration solution, 2x20 mL
sachet of electrode cleaning solutions, 9V battery, instruc-
tions, all in a rugged carrying case.
Specifications Mi106
Range (*) pH -2.00 to 16.00 pH
mV -2000 to +2000 mV
Temp -5.0 to 105.0°C / 23.0 to 221.0°F
Resolution pH 0.01 pH
mV 1 mV
Temp 0.1°C / 0.1°F
Accuracy (@25°C) pH ±0.02 pH
mV ±2 mV
Temp ±0.5°C up to 60°C; ±1°C outside / ±1°F up to 140°F; ±2°F outside
Typical EMC Deviation pH ±0.02 pH
mV ±2 mV
Temp ±0.2°C / ±0.4°F
Temperature Compensation automatic, from -5 to 80°C / 23 to 176°F
pH Calibration automatic, 1 or 2-point
ORP Calibration factory calibrated
Probe MA923D/1, amplified pH/ORP/temperature probe (included)
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type 1 x 9V alkaline (included)
Battery Life approx. 500 hours of use
Auto-off after 8 minutes of non-use
Dimensions 200 × 85 × 50 mm
Weight 260 g (with battery)
Extended Range pH/ORP/Temperature Meter
The Mi106 multi parameter portable meter is ideal for field
measurements.
The included combined pH/ORP electrode has a built-in
temperature sensor and amplifier to prevent electrical
interference.
The large display shows readings in an extended range
from -2.00 to 16.00 pH or ±2000 mV and simultaneously
shows temperature from -5.0 to 105.0°C or 23 to 221°F.
The Mi106 has a stability indicator and hold feature that
freezes the display for easy and accurate recording.
The large display also has graphic symbols to guide you
through all operations.
When switched ON it performs a self-check and displays
the percentage of the remaining battery level to assure
proper working condition.
Calibration is performed automatically at 1 or 2 points
using standard or NIST buffers.
11
www.milwaukeeinst.com
(*) The temperature range is limited to 80°C (176°F) if using the MA923D/1 probe.
pH/ORP