Specifications

13
Tru Pointe® 1100 Instruction 0028-9002
Vibration
Vibration, misalignment, or moving machinery which is not properly balanced can be deadly to
a system. These things can cause excessive wear bringing the life of any system to an early
demise.
All these problems have a common warning signal; increased ultrasonic energy. This ultrasonic
energy is generated from the friction associated with these problems, and can be detected with
the Tru Pointe
®
1100.
EXAMPLE: Maintaining a system using multiple pumps
or motors all of the same type. After testing a sample
of these bearings, the will be able to determine what
readings are normal or abnormal for each type.
REMINDER: To insure success, be consistent. If you
test a compressor bearing, for example, test the same
place, at the same sensitivity setting. It is a good idea
(although not necessary) to test units when they are
new, and keep your own records of what is acceptable
for a new piece of equipment.
See the previous section on charting your results.
WARNING! Be careful when working around rotating
machinery. The headphones will dampen much of the
sound around you. Use care, and be alert at all times.
Make certain the headphone cord is away from moving
machine parts.