Owner's Manual
Tru Pointe
Instruction 0019-9328
7
Turning the Instrument ON / OFF
See Figure 3. The instrument is toggled ON and OFF by pressing the 
on/off button.
WhentheinstrumentisrstturnedON,observethatthegreenpower on 
LED will glow, and that the red leak rateLEDashesrapidlyalongwith
the audible indicator producing a rapid ticking sound or constant tone.
The instrument requires a minimum of 10 seconds to warm up. After 
which time both the leak rate LED and audible indicator should slow 
downtonomorethan1or2ashes/tickspersecond.
Notethatduringthewarm-upperiod,theinstrumenthaszeroedoutany
background concentration of refrigerant vapors that may have been present 
in the area.
After the instrument is turned ON and allowed to warm up, it is ready 
to perform leak testing as described in Section Procedure for Locating a 
Refrigerant Leak.
Operation
Figure 3. Indicators and Controls
Green LED:
 ON = Instrument turned ON
 Blinking = Low battery condition
Amber LED:
 ON = High Sensitivity
 OFF = Low Sensitivity
 Blinking = Sensor Failure
Red LED:
 Flash rate increases when the instrument
 detects an increased level of refrigerant
Press to toggle instrument ON and OFF
Press to toggle between high and low sensitivity










