Specifications

Refrigerant Recovery System Model 3600
4
Refrigerant Recovery Rates Certified per AHRI 740-95 & 740-98
Refrigerant Liquid Rate Liquid Push-Pull Rate Vapor Rate
R-22
4.96 lb/min
2.25 kg/min
13.01 lb/min
5.90 kg/min
0.37 lb/min
0.17 kg/min
R-134A
3.86 lb/min
1.75 kg/min
11.84 lb/min
5.37 kg/min
0.29 lb/min
0.13 kg/min
R-410A
3.31 lb/min
1.50 kg/min
15.70 lb/min
7.12 kg/min
0.42 lb/min
0.19 kg/min
1.3. Features
Designed specifically for the new R-410A blend that has much higher vapor pressures.
New oilless compressor technology that is QUIETER, FASTER, AND LIGHTER than current
products on the market.
When used properly, tolerates liquid during vapor recovery operations with no compressor
damage.
Extremely easy to operate.
Extra large condensing ensures high recovery rates even on the hottest days.
Self-purging valve completely purges the condenser and tubing, eliminating cross contamination
when switching between refrigerants.
Solid state LED status display keeps the operator informed of the operational status of the unit.
The following situations are monitored: High Pressure Shutoff, Recovery Cylinder Full Shutoff (If
option is installed), Automatic Vacuum Shutoff, and System Operating.
Suction and discharge gauges eliminate the need for a manifold gauge set.
Inlet and outlet ball valves provide full refrigerant flow and positive shutoff.
Automatic vacuum shutoff at 13” HG vacuum.
Automatic high-pressure shutoff at 550 psi.
Rugged heavy-duty steel construction with epoxy powder coating for long life.
Options include: Deluxe carrying case to protect the 3600 from damage during transport,
Automatic 80% tank full shutoff.
Specifications are subject to change without notice.