was dispensed for approximately 5-10 seconds and the remainder of the time was spent filling
out the biopsy record sheet.
Nurses wore rubber latex gloves while dispensing the formalin. A plexiglass splash shield was
fixed above the formalin container. The only ventilation located in the room was the general
dilution ventilation provided by the HVAC system of the building.
According to the nurses, the formalin container is kept in its original cardboard shipping box
because it often leaks around the spigot (see photo 5 in Appendix 2). A new spigot is shipped
with each formalin container and is screwed into the new full container. This leak causes the
cardboard around the container to become wet and give off formaldehyde vapours even after
dispensing has stopped.
3.2 Maternity Ward
Labour and delivery is located on the third floor of Langley Memorial Hospital and contains 12
labour and delivery rooms. Once a patient is admitted they are assigned to a room where they
will labour, deliver and recover prior to discharge. Nitrous oxide is piped into each room from a
central supply located in the basement of the building. A sampling location plan is located in
Appendix 1 of this report and photographs can be found in Appendix 2.
The delivery rooms contain a bed, sink, sofa, bathroom and have cupboards located behind the
head of the bed that contain the nitrous oxide supply, mask, scavenging system and suction.
The nitrous oxide delivery system is a demand system. Gas is dispensed when the mother holds
the mask tightly against her face and inhales and the scavenging system is activated when the
mother exhales into the mask. Nitrous oxide exhaled into the mask is captured by the
scavenging system and exhausted to the outside. Hospital protocol states that the mother must
hold the mask at all times (and not have the father hold it) to prevent her from overdosing on the
gas (unconsciousness would result before a lethal overdose could occur). If the mother did not
have a good seal between the mask and her face then the gas could not be dispensed.