Specifications

Multi-Zone Gas Monitors
P/N: 3015-5074 Rev 10 9
The enclosure utilizes keyhole mounting brackets designed for ¼ inch fasteners. Locate the four screws as
shown in the diagram below or by using the provided mounting template (P/N 3015-5109). Allow the screw
heads to protrude approximately ¼ inch.
Figure 2-1. MZ Monitor Mounting Specifications
Hold the monitor flat against the mounting surface and allow it to slide down, engaging the screw heads in
the keyhole slots of the mounting brackets. Adjust the screws as necessary to hold the monitor securely
against the mounting surface.
2.2. Connecting Gas Sample Lines
2.2.1. Overview
Individual gas sample lines are run from the MZ monitor to each area of the facility to be monitored.
Additionally, a purge line is installed to provide clean air for resetting the infrared zero baseline. All air,
sample, and purge line connections are located on the left side of the enclosure. Refer to the illustration
below.