Specifications

Ammonia Gas Monitor – Multi Zone
Instruction 3015-5113
37
Viewing Fault Log
A data log of the last 20 fault conditions is retained in memory. On the Fault Screen, select the LOG option to
view a display of the fault log.
Fault Log Screen
This screen lists potential fault conditions in the left column and displays a check mark indicating which
problems were associated with each fault condition as represented by the vertical cursor bar. As you move
the bar horizontally using the LEFT/RIGHT cursor keys, the date and time the fault condition was detected is
displayed in the upper right hand corner of the display window.
Anytime the fault status changes, there is an entry in the fault log, both when the fault occurs and when it is
cleared.
The Fault Log can be reset by pressing a combination of the ENTER and RIGHT arrow buttons while viewing
the log.
Viewing Flow Log
On the Fault Log screen, press ENTER to access the Flow Log screen. The Flow Log displays the last 20
flow events for all zones and the purge port.
Flow Log Screen
UP/DN KEY TOGGLES ZONES
ZONES 1 - 8
This screen lists the zones in the left column and displays flow data. Use the UP/DOWN buttons to scroll
through the zones and the LEFT/RIGHT to scroll through the log data. As you move the bar horizontally, the
date and time of the condition is displayed in the upper right corner.
The Flow Log can be reset by pressing a combination of the ENTER and RIGHT arrow buttons while viewing
the log.