Specifications
Instruction 24-9395
37
Fyrite Pro
4.13.9 Temperature Differential Screen (Model 125)
The Temperature Differential reading is the measured difference between
the temperatures being measured by the T-STACK and T-AIR thermo-
couples.
Front Panel Button Functions:
– Displays next screen (refer to Section 4.12)
– Displays previous screen (refer to Section 4.12)
HOLD – Freezes display (press ENTER to unfreeze)
ENTER – Hold for 2 seconds to display Fuel Screen
LIGHT – Toggles backlight ON/OFF
I/O – Turns analyzer OFF (5 second delay)
4.13.10 Stack Temperature & Efficiency Screen
(Model 110/120/125)
The STACK reading is the temperature measured at the tip of the probe.
The EFF (Efficiency) reading is a calculation of what percentage of energy
present in the fuel was converted into usable heat.
Front Panel Button Functions:
– Displays next screen (refer to Section 4.12)
– Displays previous screen (refer to Section 4.12)
HOLD – Freezes display (press ENTER to unfreeze)
ENTER – Hold for 2 seconds to display Fuel Screen
LIGHT – Toggles backlight ON/OFF
I/O – Turns analyzer OFF (5 second delay)