Specifications
Instruction 24-9395
4
Fyrite Pro
Operating Time ................................. Up to 18 hours continuous (pump
running and backlight off)
Warm Up Time ................................... 10 or 60 seconds, dependent on
analyzer’s model and setup (Refer
to Section 4.13.1)
Memory
(Model 105/110/120/125) ..................... Up to 10 sets of readings can be
saved in memory. When memory
is full, the next reading saved will
overwrite the oldest reading.
Display ................................................. 4 Digit, 2 Line, 7-segment Liquid
Crystal Display
Front Panel Controls ....................... Six push button switches
(Refer to Section 3.4)
Accuracy:
• Oxygen............................................. ±0.3% O
2
with a typical flue gas
concentration of CO
2
• Carbon Monoxide ............................ ±5% of reading or ±10 ppm, which-
ever is greater*
• Flue Gas Temperature .................... ±4 °F between 32 & 255 °F
(±2 °C between 0 & 124 °C)
±6 °F between 256 & 480 °F
(±3 °C between 125 & 249 °C)
±8 °F between 481 & 752 °F
(±4 °C between 250 & 400 °C)
• Second Thermocouple Channel ...... ±4 °F between 32 & 212 °F
(±2 °C between 0 & 100 °C)
• Ambient Temperature..................... ±4 °F between 32 & 104 °F
(±2 °C between 0 & 40 °C)
• Draft ................................................ ±1% of reading or ±0.02 inWC
(±0.05 mB), whichever is greater
* Tighter CO accuracy in the lower ranges, up to ±2 ppm, may be
attained if a lower range calibration gas (e.g. 100 ppm CO) is used.