Specifications

Instructions 77-9045 Bacharach, Inc. Page 4-1
CD3 AUDIT KIT POST AUDIT CHECKLIST
4.0 POST AUDIT CHECKLIST
Checklist for completed audit
Calibration fluid viscosity is per chart supplied
with the Viscor cup.
Calibration fluid temperature is 104°F + 1°F.
Gear pump pressure is between 400 and 410 psi.
Body to seat clamp force is more than 167 lbs.
Plunger to body clamp force is 380 lb ± 10 lbs.
Injector supply pressure is exactly 100 psi.
Flow from dummy injector orifice is between 528
and 537 cc/min.
Discharge head upstream pressure is above 300 psi
for 60 seconds minimum.
Discharge head pressure drop is 150 psi +20, -0 psi.
Discharge head downstream pressure is above 150
psi for 30 seconds minimum.
Camshaft speed for Cummins is 1050 rpm ± 1 rpm.
Camshaft speed for GM is 2000 rpm ± 5 rpm.
Strokes occur at between 2.8 and 2.9 second inter-
vals (STROKES set at 50 and speed set at 1050
RPM).
Return all calibration tools and equipment to the
Audit Kit box or to their proper positions on the
calibrator doors.
CAUTION
Leaks from batteries can damage the
indicator. Remove batteries from the
indicator, especially if the indicator will be
stored for more than a few days.
YES NO
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____
_____ _____