Specifications

Instructions 77-9045 Bacharach, Inc. Page 3-7
CD3 AUDIT KIT DETROIT DIESEL INJECTORS
Test
5. Using the stopwatch, note the time between
flashes of the strokes indicator which appears
in the MM³/STROKE display.
The flashes should be at 3.0-second intervals.
6. Repeat step 5 three times.
7. If the stroke interval average is not 3.0 seconds
consult the CD3 manual.
8. Turn off the main drive. (Push the STOP
button.)
Figure 3-6. Stroke Count Check
ÊSTROKES SET TO 100
ÍDISPLAY