MAINTENANCE AND TROUBLESHOOTING INJECTOR CALIBRATOR CD3
4.2 TROUBLESHOOTING
4.2.1 Charts
TROUBLESHOOTING CHART FOR MECHANICAL PROBLEM
Fault Possible Cause and Remedy
_____________________________________________________________________________________________________
Plunger-to-body May lack unlocking pressure — Press HOLD TO OPERATE button and listen for valve
clamp faulty reliefs (“putt” sound).
1. If after three putts, cylinder will still not move, there may be insufficient hydraulic
pressure.
(a) Check intensifier hydraulic circuit for leaks.
(b) Check hydraulic pressure at the cylinder (Section 8.2).
2. If there are no putt sounds, check air pressure gage at secondary air pressure
regulator and make sure that solenoid valve is operative.
Clamp force not 1. Air may be in clamp system because of low oil level in the intensifier reservoir.
repeating (a) Bleed air at bleed port (Section 8.2).
(b) Fill intensifier reservoir (Section 4).
(c) Make sure all fittings and hoses leading from the reservoir to the clamp pump
are tight.
2. Faulty clamp pressure regulator — replace
Pressure drops in Pressure regulator knob may have been moved — Check that setting is correct and
injector supply locked (by tightening nut on stem).
circuit
Calibration fluid 1. Cold water supply may be turned off — Turn on supply.
temperature too
high 2. Water flow through calibrator may be disrupted — Disconnect return line with heat
lamp off at console and observe for presence of water flow.
3. Temperature control system may not be operating properly — See Chapter 2 for
proper operation.
Fuel arm leaks May be faulty or missing “O” ring — Replace “O” ring (Section 8.3).