Specifications
Instruction 0024-9435
1
Fyrite Tech
1.0 INTRODUCTION
1.1 The Fyrite Tech
Available in two models, the Fyrite Tech 50 and 60 are hand-held an a -
lyz ers that are designed to calculate the ef fi cien cy of res i den tial furnaces
and com bus tion appliances by measuring the stack temperature and the
percent oxygen level in the fl ue-gas stream.
While both analyzers are ca pa ble of com bus tion testing, the Fyrite Tech
60 has the added capability of mea sur ing carbon monoxide and calculating
CO air-free, and also has the capability of sending combustion test data to
an optional printer via an infrared port using either HP or IrDA protocol.
Fyrite Tech 50 Fyrite Tech 60
Measures: Measures:
• Oxygen (O
2
)
• Oxygen (O
2
)
• Stack Temperature • Stack temperature
• Ambient Temperature • Ambient Temperature
• Carbon Monoxide (CO)
Calculates: Calculates:
• Combustion Effi ciency • Combustion Effi ciency
• Carbon Dioxide (CO
2
) • Carbon Dioxide (CO
2
)
• Excess Air • Excess Air
• CO air-free
WARNINGS!
This analyzer is not intended to be used on a continuous
basis.
The analyzer does not have an audible alarm, and is not
in tend ed to be used as a safety device.
Except for battery replacement, this analyzer should only be
opened and ser viced by au tho rized personnel.
When testing an appliance, a full visual in spec tion of the ap-
pliance should be carried out to ensure its safe op er a tion.