Specifications

Instruction 0024-9435
23
Fyrite Tech
4.8.3 O
2
Screen (Model 50 only)
The O
2
display is the measured percentage of oxygen present in the ue-
gas stream.
Front Panel Button Functions:
/ Scrol through Run Mode Screens (refer to Section 4.7)
ENTER Hold for 2 seconds to display Fuel Screen
HOLD Freezes display (press ENTER to unfreeze)
LIGHT Toggles backlight ON/OFF
I/O Turns analyzer OFF (with a 5 second delay)
4.8.4 CO & O
2
Screen (Model 60 only)
The CO display is the measured ppm amount of carbon monoxide pres-
ent in the ue-gas stream. Note, however, that the amount of CO dis-
played may be diluted by secondary air (refer to Section 4.8.5 CO Air Free
Screen).
The O
2
display is the measured percentage of oxygen present in the ue-
gas stream.
Front Panel Button Functions:
/ Scroll through Run Mode Screens (refer to Section 4.7)
ENTER Hold for 2 seconds to display Fuel Screen
HOLD Freezes display (press ENTER to unfreeze)
LIGHT Toggles backlight ON/OFF
I/O Turns analyzer OFF (with a 5 second delay)