Specifications

Setup Monoxor
Plus Manual
12 0019-9370 Rev 0
2.3. Power Options
Power options include:
Disposable AA alkaline batteries (included)
Disposable AA lithium (Li) batteries
Externally charged rechargeable NiMH batteries.
Check the Monoxor
Plus for sufficient power prior to
each use. Replace the batteries if the low (or replace)
battery symbol appears in the upper right corner of
the Monoxor
Plus screen.
Batteries (4 AA, Fresh or Fully Charged)
Estimated Life Span in Hours
(Continuous, Pump On)
Alkaline (disposable) 15 hours
Lithium (disposable) 20 hours
Rechargeable 8 hours
Repl
ace batteries as follows.
1. Remove the battery cover from the back of analyzer.
2. If old batteries are installed, remove them and properly discard them.
3. Observing the polarity markings inside the battery compartment,
install four ‘AA’ disposable (alkaline or lithium) batteries or four fully-
charged (externally charged) AA rechargeable NiMH batteries.
4. Replace the battery cover.
NOT
E: The Monoxor
Plus does NOT charge rechargeable
batteries.
NOT
E: The Monoxor
Plus sounds a series of beeps to indicate
that the batteries need to be replaced.
netzerotools.com
netzerotools.com