Specifications

1.800.736.4666
BACHARACH
8
Applications
The ECA 450 is ideal for professionals concerned about
combustion efficiency, environmental compliance, or both.
It enables plant maintenance engineers and managers,
industrial boiler/furnace service technicians, energy
coordinators, compliance officers, environmental auditors
and safety managers to ensure that industrial equipment is burning
efficiently while environmental regulations are being met.
ORDERING INFORMATION
PART NO. DESCRIPTION
24-7221 Base Unit (O
2
, CO, T
s
, T
a
, DP)
24-7289 Base Unit (O
2
, CO, T
s
, T
a
, DP)
w/ wireless hand-held remote **
24-7223 Heavy duty sample conditioning system (EPA/ETV Test
Verified performance). Includes Peltier chiller unit with
integral condensate pump, 15’ heated hose assembly
with probe and built-in temperature controller
PART NO. PROBE ASSEMBLY
24-3024 24” probe assembly
24-3025 36” probe assembly
24-7224 Compact sample conditioner/probe assembly. Includes
Peltier chiller/probe assembly, built-in filter, condensate
pump and 15’ hose assembly
24-3035 24” High temperature probe assembly
24-3036 36” High temperature probe assembly
24-3037 48” High temperature probe assembly
24-1124 20 ft hose extension
24-1172 Water Trap/Filter Assembly (for probe hose assembly)
PART NO. SENSORS (factory installed into new units)
24-3026 CO (high) Sensor
24-3027 NO Sensor
24-3028 Combustible Sensor
24-3029 NO
2
Sensor
24-3030 SO
2
Sensor (requires NO
2
option)
PART NO. ACCESSORIES
07-1644 Filters (pkg. of 3)
24-7059 Calibration Kit (does not include gas)
104-1800 Thermocouple Wand Extension, 5 feet
104-4027 Serial Cable DB.9M to DB.9F
24-0980 Printer Paper (5 rolls)
The maximum operating temperature for probes included in 24-7221, 24-7224, 24-7223,
24-3024 and 24-3025 is 1472
O
F (800
O
C). The maximum operating temperature for high
temperature probes 24-3035, 24-3036 and 24-3037 is 2000
O
F (1093
O
C).
** The wireless, hand-held remote is recommended for use of up to 300 ft. indoors
with normal obstructions and up to 1,000 ft. outdoors.
TECHNICAL DATA
Measurements & Ranges
Oxygen 0.1 to 20.9%
Carbon Monoxide 0 to 4000 ppm
(hydrogen compensated) (hydrogen compensated)
Carbon Monoxide (high)* 4001 to 80000 ppm
Nitric Oxide* 0 to 3500 ppm
Nitrogen Dioxide* 0 to 500 ppm
Sulfur Dioxide* 0 to 4000 ppm
Combustibles* 0 to 5.00% (application dependent)
Stack Temperature -4 to 2400 degrees F (-20 to 1215˚ C)
Primary/Ambient Temperature -4 to 999 degrees F (-20 to 999˚ C)
Pressure/Draft -27.7 to 27.7 inches of H
2
O
Calculations & Ranges
Combustion Efficiency 0.1 to 100.0%
Excess Air 1.0 to 250%
Carbon Dioxide (dry basis) 0 to fuel dependent maximum
NO
X
(NO
X
=NO+NO
2
) 0 to 4000 ppm
NO
X
referenced to % O
2
0 to 17000 ppm
CO referenced to % O
2
0 to 99999 ppm
NO referenced to % O
2
0 to 14900 ppm
NO
2
referenced to % O
2
0 to 2100 ppm
SO
X
referenced to % O
2
0 to 17000 ppm
Accuracy
Oxygen ±0.3% O
2
on practical concentration of
flue gas
Stack or Flue Gas Temp. ±4°F between 32 and 255°F
2°C between 0 and 124°C)
± 6°F between 256 and 480°F
3°C between 125 and 249°C)
± 8°F between 481 and 752°F
4°C between 250 and 400°C)
Primary-air/ambient Temp. ± 2°F between 32 and 212°F
1°C between 0 and 100°C)
Pressure Draft ±2% of reading or ±.02 in wc
whichever is greater
CO ±5% of reading or ±10 ppm whichever is greater between
0-2000 ppm CO
±10% of reading between 2001 to 40000 ppm CO
NO ±5% of reading or ±5 ppm whichever is greater between
0-2000 ppm NO
NO
2
±5% of reading or ±5 ppm whichever is greater between
0-500 ppm NO
2
SO
2
±5% of reading or ±10 ppm whichever is greater between
0-2000 ppm SO
2
HC ±5% of full scale
Selectable Fuels Natural Gas, Oil #2, Oil #4, Oil #5, Oil #6,
Propane, Coal, Wood, Kerosene, Bagasse
Power Universal AC adapter and an internal battery pack.
Adapter will accept input voltages from 100 to
240V. Fully charged battery pack provides a
minimum of 8 hrs of operation
Pumps & Probe Two pumps are included. The first pump supplies gas
sample to the sensors. The second pump supplies
fresh air to purge the low range CO sensor when CO
levels exceed 4000 ppm. Probe includes a standard
probe and hose assembly equipped with a water trap,
particulate filter, probe stop, 15 feet of hose, and
12-inch probe tube.
Size 13.5” H x 18.5” W x 9” D
Weight 25 lbs. (11.34 kg)
Warranty 1 year, extended warranty available
* Optional