Specifications

1.800.736.4666
BACHARACH
32
Applications
Energy audit testing
Furnace and boiler servicing or replacement
Environmental emissions monitoring
Analyzing indoor air quality (IAQ)
Spot checking continuous emission systems
Safety checks on combustion stack gas
ORDERING INFORMATION
Single Gas Analyzers
Family of Products
Light and rugged, Bacharach’s family of hand-held digital analyzers measure toxic gases or oxygen.
Now you can quickly measure and display levels of oxides of nitrogen (NO
X
), sulfur dioxide (SO
2
),
carbon monoxide (CO) or oxygen (O
2
) more accurately, efficiently and economically than ever before.
Just turn on the instrument, zero it, insert the probe into the stack or air being sampled. The analyzer
will continuously measure and display readings of a specific gas. Single gas analyzers operate on four
replaceable C-size batteries for approximately 14 continuous hours of operation.
PART NO. DESCRIPTION
19-8004 Monoxor II in carrying case
19-8005 Oxor II in carrying case
19-8006 Nonoxor II in carrying case
19-8007 Dioxor II in carrying case
19-8001 Replacement NO
X
sensor
19-8002 Replacement SO
2
sensor
24-7070 Replacement O
2
sensor
19-3076 Probe & hose assembly
19-0441 Adjustment screwdriver
11-0121 Filtering material for water trap
19-0377 Replacement carrying case
24-0519 Replacement CO Sensor
SPECIFICATIONS (for all instruments)
Nonoxor
®
II (NO
X
) Dioxor
®
II (SO
2
) Oxor
®
II (O
2
) Monoxor
®
II (CO)
Range 0-2,000 ppm 0-2,000 ppm 0-25.5% 0-2,000 ppm
Factory Calibrated 100 ppm NO 100 ppm SO
2
10% O
2
500 ppm CO
Instrument Accuracy ±5% of reading ±5% of reading ±.5% of reading ±5% of reading
Sensor Life (typical) 2 years 2 years 1 year 2 years
Readout Four-digit LCD display featuring 1/2” high digits, low battery and
over-range indicator
Battery Supply Four replaceable, C-size batteries (not included)
Max. Probe Exposure 1000°F (538°C)
Pump Draw Sample draw of instrument is suitable for up to 1 inch of water