User Guide

Fyrite
InTech
Manual Configuration
0024-9486 Rev 4 17
Section 3. Configuration
3.1. Menu Structure Overview
NOTE: The Fyrite
InTech
may be configured to use either North
American combustion equations or Siegert combustion equations
(see page 32). As a result, several parameters are unique to each
configuration. This section shows a mix of screens that have been
configured for North American combustion equations as well as
Siegert combustion equations. Depending on how you have
configured your instrument, your screens may vary slightly from
those pictured in this section.
Menus and the items contained within them are described in a top-down
fashion, starting from the startup screens and working sequentially through the
menus and menu items.
3.2. The Warm-up Sequence
Boot Screens
Description
Splash screen shows the Bacharach logo with
version, model number, and serial number
information. This screen is displayed for
approximately 3 seconds.
A warm-up screen is displayed during which the
instrument is purged and initialized. A countdown
timer is displayed with the current zero setting for
the CO sensor (Auto-Zero or Manual Zero) (see page
31 and page 58).
If any errors are detected during warm-up, the
corresponding error messages are displayed, after
which the user presses F2 to go to the Menu, or
presses RUN/HOLD to go to the Hold screen. (See
page 61 for a list of error messages.)