Overview of Primary Product

Murco Limited is A Bacharach Company. Bacharach
®
is a registered trademark of Bacharach, Inc.
©2011. Murco Limited, all rights reserved. All information is subject to verification.
October 2011 – Rev. 0
Made in the USa
Distributed By:
Single-Zone Ordering Information
3015-4200 HGM-SZ Halogen Gas Monitor - Single Zone
(with termination lter, 15.24 m of sample tubing,
& 15.24 m (50 ft.) exhaust/purge line tubing)
3015-4280 AGM-SZ Ammonia Gas Monitor - Single Zone
(with termination lter, 15.24 m of sample tubing,
15.24 m (50 ft.) exhaust/purge line tubing)
0304-2742 AGM-SZ Sample/Exhaust/Purge Line Tubing
0304-2743 HGM-SZ Sample/Exhaust/Purge Line Tubing
(note: #0304-2742 is req'd for AGM-SZ sample line)
3015-3420 Termination lter
3015-4121 120 VAC surge protector
3015-4122 220 VAC surge protector
3015-4123 4-20 mA surge protector
3015-5490 24 VDC Audible/Visual Audible Alarm
3015-3492 24 VDC Visual Alarm
3015-3076 120 VAC External Audible/Visual Alarm
3015-5529 Single-Zone Annual Maintenance Kit
Single-Zone Specifications
R-11, R-12, R-22, R-23, R-113, R-114,
R-123, R-124, R-125, R-134a, R-227,
R236FA, R-401a, R-402a, R402b,
R-404a, R-407a, R-407c, R-408a,
R-409a, R-410a, R-500, R-502, R-503,
R-507, R-508b, H-1211, H-1301,
H-2404, N-1230
0 to 1,000 ppm
1 ppm
± 1 ppm ± 10% of reading from 0 to
1,000 ppm
Single-pass Non-Dispersive Infrared (NDIR)
3 SPDT, 3 Amp, 250 VAC rated alarm relays and 1 SPDT, 3 Amp, 250 VAC rated
system fault relay, plus a digital display with dedicated 4-20 mA DC analog
output (oating ground)
Maximum 152.4 m (500 ft.) from measuring point to monitor
100 to 240 VAC, 50/60 Hz
Green LED: indicates unit is operating properly
Yellow LED: indicates clogged sample line or other system fault
Red LED:
indicates when any monitored point exceeds alarm settings
Dedicated single zone
9 to 90 seconds, depending on sample tube length
UL 61010-1 • CSA 22.2 No. 61010-1 • EN 14624 • CE Mark
13.7" x 7.7" x 3.6" / 7 lbs. (347.98 mm x 195.58 mm x 91.44 mm / 3.175 kg)
Ammonia (NH
3
) - also known as
R-717
25 to 10,000 ppm
25 ppm
± 20 ppm ± 10% of reading from 25
to 1,000 ppm
Part Number:
Includes:
Measures:
Measuring Range:
Sensitivity:
Accuracy:
Detector Type:
Output Signal:
Monitoring Distance:
Power:
Front Panel Display:
Inputs:
Response Time:
Approvals:
Size / Weight:
HGM-SZ AGM-SZ
3015-4200
HGM-SZ single zone monitor with:
1 termination lter, 15.24 m (50 ft.) of
sample line tubing.
3015-4280
AGM-SZ single zone monitor with:
1 termination lter, 15.24 m (50 ft.) of
sample line tubing.