Overview of Primary Product

Bacharach
®
is a registered trademark of Bacharach, Inc.
©2012. Bacharach, Inc., all rights reserved. All information is subject to verication.
September 2012 – Rev. 2 Printed in U.S.A.
PCA
®
3 Ordering Information
N. AM EU
0024-8440 0024-8460 PCA
®
3 225 (O
2
, CO)
0024-8441 0024-8461 PCA
®
3 235 (O
2
, CO, NO)
0024-8442 0024-8462 PCA
®
3 245 (O
2
, CO, CO high)
0024-8443 0024-8463 PCA
®
3 255 (O
2
, CO, SO
2
)
0024-8444 0024-8464 PCA
®
3 265 (O
2
, CO, NO, NO
2
)
0024-8445 0024-8465 PCA
®
3 275 (O
2
, CO, NO, SO
2
)
0024-8446 0024-8466 PCA
®
3 285 (O
2
, CO, NO, CO high)
0024-8447 0024-8467 PCA
®
3 225 Kit (O
2
, CO, printer)
0024-8448 0024-8468 PCA
®
3 235 Kit (O
2
, CO, NO, printer)
0024-8449 0024-8469 PCA
®
3 245 Kit (O
2
, CO, CO high, printer)
0024-8450 0024-8470 PCA
®
3 255 Kit (O
2
, CO, SO
2
, printer)
0024-8451 0024-8471 PCA
®
3 265 Kit (O
2
, CO, NO, NO
2
, printer)
0024-8452 0024-8472 PCA
®
3 275 Kit (O
2
, CO, NO, SO
2
, printer)
0024-8453 0024-8473 PCA
®
3 285 Kit (O
2
, CO, NO, CO high, printer)
PCA
®
3 Replacement Parts & Accessories
0024-1541 B-Smart
®
CO (H
2
Compensated) Sensor
0024-1542 B-Smart
®
CO (high range) Sensor
0024-1545 B-Smart
®
NO Sensor
0024-1544 B-Smart
®
NO
2
Sensor
0024-1543 B-Smart
®
SO
2
Sensor
0024-0788 Replacement O
2
Sensor
0024-0789 Replacement CO Sensor
0024-0881 Replacement NO Sensor
0024-0997 Replacement CO (high range)
0024-0998 Replacement SO
2
Sensor
0024-1027 Replacement NO
2
Sensor
0024-1400 IrDA Printer w/Disposable Batteries (comes with Reporting Pkg. Kit)
0024-1310 Printer Paper (5 rolls)
0006-8733 Printer Paper (1 roll)
0024-1254 Universal AC Power Adapter (110-240V)
0007-1644 Replacement Filter Element (pkg. of 3)
0024-7224 Compact Sample Conditioner*
0024-3004 Replacement Probe Assembly (North American)
0024-3053 Replacement Probe Assembly (European)
0024-1124 20 ft. Hose Extension with Sample, Draft and Thermocouple Lines
0024-1470 Fyrite
®
User Software
0021-7006 Tru Spot Smoke Tester
PCA
®
3 Specifications
North American Version European Version
Measurement Ranges:
Primary/Ambient Air Temperature
-4
o
to 999
o
F -20
o
to 537
o
C
Stack Temperature -4
o
to 2192
o
F -20
o
to 1200
o
C
Oxygen 0.1 to 20.9% 0.1 to 20.9%
Carbon Monoxide 0 to 4,000 ppm 0 to 4,000 ppm
(H
2
Compensated)
Carbon Monoxide (High Range) 4,001 to 20,000 ppm 4,001 to 20,000 ppm
Nitric Oxide 0 to 3,000 ppm 0 to 3,000 ppm
Nitrogen Dioxide 0 to 500 ppm 0 to 500 ppm
Sulfur Dioxide 0 to 5,000 ppm 0 to 5,000 ppm
Pressure +/- 72 inwc +/- 179 mB
Calculated Ranges:
Combustion Efciency 0.1 to 100.0 % EFF 0.1 to 100.0%
ETA 0.1 to 112.0%
(Fuel Dependent)
Stack Loss ---- qA 0.1 to 100.0%
Excess Air 1.0 to 250% Lambda 1 to 9.55%
Carbon Dioxide 0 to Fuel Dependent Maximum 0 to Fuel Dependent Maximum
NO
x
(NO + NO
2
) 0 to 3500 ppm 0 to 3500 ppm
NO
x
(Calculated from NO) 0 to 3500 ppm 0 to 3500 ppm
NO
x
Referenced to %O
2
0 to 9999 ppm 0 to 9999 ppm
CO Referenced to % O
2
0 to 9999 ppm 0 to 9999 ppm
NO Referenced to % O
2
0 to 9999 ppm 0 to 9999 ppm
NO
2
Referenced to % O
2
0 to 9999 ppm 0 to 9999 ppm
SO
2
Referenced to % O
2
0 to 9999 ppm 0 to 9999 ppm
CO/CO
2
---- 0.0001 to Fuel Dependent
Maximum
Selectable Fuels: Natural Gas Natural Gas
Oil #2 KOKS
Oil #4 LEG
Oil #6 Propane
Propane Oil #2
Coal Oil #6
Wood Coal
Kerosene BioFuel
Bagasse LPG
Digester Gas Butane
Accuracy:
Oxygen +/- 0.3% O
2
(Flue Gas)
Stack Temperature +/- 4
o
F between 32
o
to 255
o
F +/- 2
o
C between 0
o
to 124
o
C
+/- 6
o
F between 256
o
to 480
o
F +/- 3
o
C between 125
o
to 249
o
C
+/- 8
o
F between 481
o
to 752
o
F +/- 4
o
C between 250
o
to 400
o
C
Primary/Ambient Air Temperature
+/- 2
o
F between 32
o
to 212
o
F +/- 1
o
C between 0 o to 100
o
C
Pressure/Draft +/- 0.02 inwc between -1 to 1 inwc +/- 0.05 mB between -2.49 to 2.49 mB
+/- 2% Reading between -10 to 10 inwc
+/- 2% Reading between – 24.9 to 24.9 mB
+/- 3% Reading between -40 to 40 inwc
+/- 3% Reading between -100 to 100 mB
CO +/- 5% of reading or 10 ppm in the range of 0 to 2000 ppm CO
+ 10% of reading in the range of 2001 to 4000 ppm
NO +/- 5% of reading or 5 ppm whichever is greater in the range of 0 to 2000 ppm NO
NO
2
+/- 5% of reading or 5 ppm whichever is greater
SO
2
+/- 5% of reading or 10 ppm whichever is greater in the range of 0 to 2000 ppm SO
2
Dimensions: 9” x 3” x 2 ½” 22.9 cm x 7.6 cm x 6.3 cm
Weight: 1.4 lbs (w/batteries) 0.6 kg (w/batteries)
Body Materials: Durable ABS Housing/Rugged Rubberized Over-molding and Protective Boot w/Magnet
User Interface: Full Color Graphic Display (320 x 240 pixels), Optional Infrared Printer
Operating Temperature Range: 32
o
to 104
o
F 0
o
to 40
o
C
Operating Humidity Range: 15-90% RH Non-condensing
Power: 4 AA Alkaline Batteries
Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz)
Battery Life: Minimum of 10 Hours of Operation
Approvals: CE Mark • EN 55011, EN 50270, CE Mark, EN 50379-2
Made in the USa
PCA
®
3 Kit
PCA
®
3 Combustion Analyzer, 12” Probe Assembly,
Protective Boot w/Magnet, Fyrite
®
User Software,
USB Cable, Replacement Filter Element (pkg. of 3),
8 ‘AA’ Alkaline Batteries, Hard Carrying Case and
Printer
PCA
®
3 Basic
PCA
®
3 Combustion Analyzer, 12” Probe Assembly,
Protective Boot w/Magnet, Fyrite
®
User Software,
USB Cable, Replacement Filter Element (pkg. of 3), 4
AA’ Alkaline Batteries and Hard Carrying Case
Distributed By:
All instruments can be upgraded to include combinations of CO (high), NO, NO
2
and SO
2
*The Compact Sample Conditioner is recommended when measuring NO
2
and
SO
2
to ensure the highest degree of measurement accuracy.