Datasheet
2012
p. 11/20
Valve for
actuator size
[Ø mm]
Type Pressure
inlet P (valve
body)
Service
port A
(banjo bolt)
Orifi ce
[mm]
QNn
value air
[l/min]
Pressure
range
[bar]
Electrical coil
connection
Ind. Std.
Power
consumption
[W]
Item no. Voltage/
frequency [V/Hz]
024/DC 230/50
40 6012P Tube fi tting ø6 mm G 1/8 1.2 48 0-10 Form B 4 552 287 552 290
40 6012P G 1/8 G 1/8 1.2 48 0-10 Form B 4 552 299 552 302
40 6012P G 1/4 G 1/8 1.2 48 0-10 Form B 4 552 295 552 298
50-63 6012P Tube fi tting ø6 mm G 1/4 1.2 48 0-10 Form B 4 552 283 552 286
50-125 6014P G 1/4 G 1/4 2 120 0-10 Form A 8 424 103 424 107
175-225 6014P G 1/8 G 1/4 2.5 174 0-6 Form A 8 786 014 786 015
175-225 0331P G 1/4 G 1/4 3 194 0-10 Form A 8 – 041 233
Ordering chart for accessories
3/2-way pilot valves with banjo bolts
Seal material valve FKM, seal material banjo bolt NBR
For further accessories see Type 1062, or the accessories datasheet Type 2XXX for the full options programme.
Item no.
Type 2507, Form B Industrial standard, 0 to 250 V without circuitry
(Type 6012 P) 423 845
Type 2508, Form A acc. DIN EN 175301-803, 0 to 250 V without circuitry
(Type 6014 P, Type 0331P) 008 376
Cable plug Type 2507, Form B or Type 2508, Form A
Note: For design reasons, some of the accessories cannot be supplied for actuator size Ø 40, 175 and 225 mm. Please request the accessories datasheet Type 2XXX.