Data Sheet
p. 17/18
2012 System On/Off
CLASSIC 8801-GA
Operating data
= mandatory fields to fill out Quantity Required delivery date
Pipeline
Process medium
Type of medium
Liquid Steam Gas
Temperature at valve inlet
Valve features
DN PN
Company Contact person
Customer no. Department
Address Tel./Fax
Postcode/town E-Mail
Valve system On/Off Classic Type 8801-GA – request for quotation
Please fill out and send to your nearest Bürkert facility* with your inquiry or order
Note
You can fill out
the fields directly
in the PDF file
before printing
out the form.
standard unit
Flow rate (Q, QN, W)
1)
Absolute pressure at valve inlet
Body material
Actuator material
Stainless steel Gunmetal
PA PPS
PTFE NBR Other
Seat sealing material
Nominal pressure
PN
Nominal size
DN
Welded Internal thread Clamp
Type of connection
ISO DIN ANSI JIS Other
Standard connection
NC
2)
NO
2)
Double-acting
Function
min. max.
Pilot pressure
1)
standard unit: Liquid Q = m
3
/h; Steam W = kg/h; Gas Qn = nm
3
/h
2)
NC: normally closed by spring action; NO: normally open by spring action
Pipe material
Automation unit features
Click on the orange box „More info“… you will come to our website for the resp. product where you can download the data sheet.
Electrical position feedback
Type 8697
For actuator size 40 … 225
• LED position indicator
• Mechanical or inductive limit switches for end position registering
• Housing with IP65/IP67, 4X rating protection
• Optional intrinsically safe version acc. to ATEX / IECEx
Position feedback switches Electrical connection
Micro switch 24 V DC Cable gland
Micro switch 50 … 225 V DC/AC
Inductive switch 3-wire PNP M12 connector
Inductive switch 2-wire NAMUR (applicable only with
Inductive switch 2-wire 24 V DC inductive switch 3-wire PNP)
Number of Position Approval
feedback switches ATEX cat. 3GD, IECEx
2x ATEX cat. 2DG, IECEx
without
More
info.