Data Sheet
2012
p. 11/18
Valve for
actuator size
[Ø mm]
Type Pressure
inlet P (valve
body)
Service
port A
(banjo bolt)
Orifice
[mm]
Q
Nn
value air
[l/min]
Pressure
range
[bar]
Electrical coil
connection
Ind. Std.
Power
consumption
[W]
Article no. Voltage/
frequency [V/Hz]
024/DC 230/50
40 6012P Tube fitting Ø6
mm
G ⅛ 1.2 48
0 … 10 Form B 4
552287
552290
40 6012P G ⅛ G ⅛ 1.2 48 0 … 10 Form B 4
552299
552302
40 6012P G ¼ G ⅛ 1.2 48 0 … 10 Form B 4
552295
552298
50 … 63 6012P Tube fitting Ø6
mm
G ¼ 1.2 48 0 … 10 Form B 4
552283
552286
50 … 125 6014P G ¼ G ¼ 2 120 0 … 10 Form A 8
424103
424107
175 … 225 6014P G ⅛ G ¼ 2.5 174 0 … 6 Form A 8
786014
786015
175 … 225 0331P G ¼ G ¼ 3 194 0 … 10 Form A 8 –
041233
Ordering chart for accessories
3/2 way pilot valves with banjo bolts
Seal material valve FKM, seal material banjo bolt NBR
For further accessories see Type 1062, or the accessories datasheet Type 2XXX for the full options programme.
Note: For design reasons, some of the accessories cannot be supplied for actuator size Ø 40, 175 and 225 mm. Please request the accessories datasheet Type 2XXX.
Article no.
Type 2507, Form B Industrial standard, 0 … 250 V without circuitry (Type 6012 P)
423845
Type 2508, Form A acc. DIN EN 175 301 - 803, 0 … 250 V without circuitry (Type 6014 P, Type 0331P)
008376
Cable plug Type 2507, Form B or Type 2508, Form A