User's Manual

37
APPLICATIONS INFORMATION
SIGNAL/DATA ACQUISITION AND CONTROL
SmartMesh IP software includes embedded application support for sampling temperature, WSM2400’s
ADC and GPIO inputs, and support for actuating GPIO outputs. The Onchip Application Protocol (OAP)
enables these functions via data packets sent through the network manager over the air, removing the
need for a microprocessor connected to the mote or embedded software development on WSM2400.
SOLDERING INFORMATION
The 505-10368-00 and 505-10369-00 are suitable for both eutectic PbSn and RoHS-6 reflow. The
maximum reflow soldering temperature is 260°C. A more detailed description of layout
recommendations, assembly procedures and design considerations is included in the 505-10368-00 and
505-10369-00 Hardware Integration Guide.