Specifications
208 Chapter 9—Menu Reference
See Chapter 9, Primitive Devices, for more information on how you
can set the startup delay and initial value of a Clock device by setting
the pin delay and inversion on the output pin.
One Shot Parameters Box
When a single One Shot device is selected, the following parameters box is
displayed:
The controls in this box are summarized in the following table:
See Chapter 9, Primitive Devices, for more information on how you
can set the initial value of a One Shot device by setting the inversion on
the output pin.
High This text box allows you to edit the high time setting of the
selected clock device. Allowable settings are in the range 1
to 32,767.
Delay This text box allows you to edit the delay time setting of the
selected device. Allowable settings are in the range 1 to
32,767.
Width This text box allows you to edit the width time setting of the
selected device. Allowable settings are in the range 1 to
32,767.
LW Reference.bk Page 208 Monday, December 15, 2003 5:59 PM