Specifications

B&K Components Device Interface Protocol (BKC-DIP) Specification
Version 2.01.00
Updated 01/24/07
Page 42 of 54
LEDs should be active at a time:
Electrical Bank A
UP, LEVEL, MODE, SOURCE, PRESET, SLEEP, ENTER, MENU, DOWN
Electrical Bank B
CENTER LEVEL, SUB LEVEL, GROUP LEVEL, REAR LEVEL, ZONE 2
Therefore:
(00, D, L, T00, 0=48;cs16) Invalid, both PRESET and ENTER cannot
be active
(00, D, L, T00, 0=04;cs16) Valid, only MODE active
(00, D, L, T32, 0=02, 1=01;cs16) Invalid, both LEVEL and DOWN cannot be
active. Different LED buffers, but the same
electrical bank
(00, D, L, T64, 1=41;cs16) Valid, DOWN and ZONE 2 are in different
electrical banks, but the same LED buffer
NOTE: For a complete listing of the LED mapping, see the product specific Appendix K.
X (executive) Command
The "X", eXecutive, commands are sent by the host to access various high level functions directly.
As the number of supported eXecutive commands varies per product, please see the product
specific Appendix L for details. In general, some or all of the following eXecutive commands
may be supported:
Recall Preset Command: (receiveID, X, 0, z=nn; cs16)
Save Preset Command: (receiveID, X, 1, z=nn, autoNameMode; cs16)
Power State Command: (receiveID, X, 2, z=onOff; cs16)
Noise Generator State Command: (receiveID, X, 3, state; cs16)
Noise Steering Command: (receiveID, X, 4, speakerIndex=onOff, ... speakerIndex=onOff; cs16)
Noise Increment Command: (receiveID, X, 5; cs16)
Cold Boot Command: (receiveID, X, 6; cs16)
Factory Reset Command: (receiveID, X, 7; cs16)
WARNING!: Issuing a Factory Reset Command will destroy all user modified
data in the unit (preset, system settings, etc.).
Reinitialize BKC-DIP State Command: (receiveID, X, 8; cs16)
Test Tone State Command: (receiveID, X, 9, level; cs16)
Mute State Command: (receiveID, X, A, z=muteState; cs16)