..., 00="Zone 1 Title", ...
00 parameter identifier (in this case, the Z1 preset title)
= delimits identifier on left, value on right
"Zone 1 Title" parameter value (in this case a string)
..., 01=60, ...
01 parameter identifier (in this case, Z1 volume)
= delimiter
60 parameter value (in this case, 60h or 0 dB)
Note that parameter identifier, equal sign, and parameter value are delimited by ",", the ASCII
comma character. All of the parameter identifiers do not need to be specified. This is to allow
only specific parameters to be updated.
For example:
(00, S, P2=0A, 00="New Z2 Title", 01=4D;cs16)
where only the parameter 00 (Z2 preset title) and parameter 01 (Z2 volume) are modified.
NOTE: For a complete listing of preset parameter identifiers and maximum values for applicable
zones see the complete listing in the product specific Appendix A.
System Settings: (receiveID, S, S, identifier=value,...identifier=value; cs16)
Analogous to setting presets, system settings may also be modified.
In the following Reference 30 example, parameter 00 (V1 Input title) and parameter 08 (left
speaker offset level) are modified in units with Receive IDs of 00h.
(00, S, S, 00="VCR1", 08=03; 04F6)
In this example, the V1 Input title has been modified to "VCR1" and the left speaker offset level is
now 03h (or –10.5 dB).
NOTE: For a complete listing of system parameter identifiers and maximum values see the
complete listing in the product specific Appendix B.
Zone Adjustment (Hardware Special) Settings: (receiveID, S, H,
identifier=value,...identifier=value; cs16)
Analogous to setting presets, zone adjustment (hardware special) settings may also be modified.
In the following CT600.3 example, parameter 00 (Zone A Room EQ Bass Gain) and parameter 02
(Zone C Room EQ Bass Gain) are modified in units with Receive IDs of 00h.
(00, S, H, 00=00, 02=01;)
In this example, the Zone A Room EQ Bass Gain is now at -18.0 dB and Zone C Room EQ Bass
Gain is now at -17.5 dB.
NOTE: For a complete listing of zone adjustment (hardware special) parameter identifiers and