User guide

7
Average Command
Response Time
<50 ms <50 ms
Power Factor Correction
0.99
(Full load)
0.99
(Full load)
Remote Sense
Compensation
2 V 2 V
Rising Time at Full Load 25 ms 30 ms
Rising Time at No Load 25 ms 30 ms
Falling Time at Full Load 25 ms 30 ms
Falling Time at No Load 1000 ms 1000 ms
Transient Response Time 1 ms
Efficiency 80 %
AC Line Rated Input
Voltage
100
240 VAC
( Full load )
Tolerance/Variation in
Voltage
-15 %
+10 %
( 10 % power de-rating mode
when voltage under 95 VAC )
Rated Frequency
47 Hz63 Hz
Maximum Rated Input
Power
1700 VA
Temperature Ratings(O) Operation (0 °C -- 40 °C)
Temperature Ratings(S) Storage (-10 °C -- 70 °C)
Dimensions(W*H*D) 16.5 x 1.7 x 17 inch (420 x 43.6 x 432 mm)
Weight 19.8 lbs. (9 kg)
Standard Accessories
Power Cord, Terminal Blocks for Rapid Plug
Connector, Rackmount Kit, Manual
Standard Interface USB
Option Interface LAN & GPIB
Specifications and information is subject to change without notice