User Manual

1-35
4. Operation Instructions
4.1 Voltage Setting
Press
and set the output voltage by pressing the numerical keys directly,
and then press to confirm the setting.
4.2 Current Setting
Press and set the output current by pressing the numerical keys directly
and then press to confirm the setting.
4.3 Over-voltage Protection OVP
Press to enter the Configuration menu and press to enter the
PROTECTION setting menu. Then, using the knob set OVP to ON and press
to confirm it. Now the cursor will move to the value setting for the OVP
on the right hand side. Enter the OVP value here by pressing the numerical keys.
4.4 Over-current Protection OCP
Press to enter the Configuration menu and press to enter the
PROTECTION setting screen. Then, use the knob to set OCP to ON and press
to confirm it. Now the cursor will move to the value setting for the OCP
=
.