2.15 Multi-unit Connection Mode (RS485)
The power supply, via the RS485 interface, provides multi-unit control
function for up to 30 units (If connecting more than 10 units, please add a 120Ω
resistor terminator to the last unit as shown in the figure below). Turn on the
system after the connection is made. Press on the main page
and set CHAIN ON/OFF to ON (Parallel connection will be cancelled). Set each
unit with a different Address (1 - 30). Then by using USB, GPIB, or LAN,
connect the first power supply in the chain to a PC. Now, multiple units daisy-
chained via RS485 can be controlled by one PC by using the commands specific
for multi-unit connection. See “Remote Communication Protocol” section
for details.