User Manual
41
Local/Analog
Pin 8 can be used to select the control mode (Local or Analog) of the power
supply’s output. When the input command for this pin is at High level (or
open), the control mode will be Local. When input command for this pin is
at Low level (or connected to common GND), the control mode will be
Analog. In analog mode, setting and measurement resolution for voltage
and current will be less than local mode. See the below figures as an
example.
Local Control
V = 300.00 V I = 1.000 A OFF
0.00 V 0.000 A
Analog Control
V = 300.0 V I = 1.00 A OFF
0.0 V 0.00 A
EXTERN
ENABLE
Local/Analog pin
state
Output
control
Display
NOT ACTIVE
(by Default)
NOT ACTIVE
Local
NO
DISPLAY
ACTIVE
High (5V)
Local
Low (0V)
Analog
Local/Analog State
Pin 21 can be used to indicate the current output control mode of the power
supply (Local or Analog state). In Local state, this pin will output a High