User Manual
41 
Local/Analog 
Pin 8 can be used to select the control mode (Local or Analog) of the power 
supply’s output. When the input command for this pin is at High level (or 
open), the control mode will be Local. When input command for this pin is 
at Low level (or connected to common GND), the control mode will be 
Analog. In analog mode, setting and measurement resolution for voltage 
and current will be less than local mode. See the below figures as an 
example.   
Local Control 
 V = 300.00 V I = 1.000 A OFF
 0.00 V 0.000 A
Analog Control 
 V = 300.0 V I = 1.00 A OFF
 0.0 V 0.00 A
EXTERN 
ENABLE 
Local/Analog pin 
state 
Output 
control 
Display 
NOT ACTIVE 
(by Default) 
NOT ACTIVE 
Local 
NO 
DISPLAY 
ACTIVE 
High (5V) 
Local 
Low (0V) 
Analog 
Local/Analog State 
Pin 21 can be used to indicate the current output control mode of the power 
supply (Local or Analog state).    In Local state, this pin will output a High 