User Manual
23
XLN15010 – 10.45 A max.
XLN30052 – 5.25 A max.
XLN60026 – 2.65 A max.
VOLT LIMIT MIN:
Lower limit of the output voltage setting.
5 V min. for all models.
CURR LIMIT MIN:
Lower limit of the output current setting
XLN15010 – 0.04 A min.
XLN30052 – 0.02 A min.
XLN60026 – 0.01 A min.
VOLT SLEW RATE:
Voltage ascending/descending slope
XLN15010 – 0.01 – 1 V/ms
XLN30052 – 0.01 – 3.3 V/ms
XLN60026 – 0.01 – 6.6 V/ms
CURR SLEW RATE:
Current ascending/descending slope
XLN15010 – 0.001 – 0.104 A/ms
XLN30052 – 0.001 – 0.052 A/ms
XLN60026 – 0.001 – 0.026 A/ms
3. PROTECTION SETTING (PROTECTION)
Press
key in the first screen of the menu to enter PROTECTION
menu.
OVP: Enables/disables
SET: Set up the overvoltage
OVP = OFF SET = 306.00 V
OCP = OFF SET = 5.3040 A
OPP = OFF SET = 1560.00 W