Datasheet
v042516
6 www.bkprecision.com
High Power Programmable DC Power Supplies
PVS Series
Model PVS60085 PVS60085MR PVS10005
Output Rating
Output Voltage
(1)
0 - 600 V 0 - 1000 V
Output Current
(2)
0 - 8.5 A 0 - 5 A
Max. Output Power 5100 W 3000 W 5000 W
Line Regulation
Voltage 60 mV 100 mV
Current 4.25 mA 2.5 mA
Load Regulation
Voltage 60 mV 100 mV
Current 8.5 mA 5 mA
Ripple and Noise (20 Hz - 20 MHz)
Voltage ≤100 mVrms / ≤500 mVpp ≤100 mVrms / ≤600 mVpp
Current 15 mA 10 mA
Resolution
Programming 10 mV/0.2 mA 0.1 V/0.1 mA
Readback 10 mV/0.2 mA 0.1 V/0.1 mA
Programming Accuracy
Voltage 400 mV 700 mV
Current
(3)
± (%output + offset) 0.03% + 3.5 mA 0.03% + 2 mA
Readback Accuracy ± (%output + offset)
Voltage 0.05% + 300 mV 0.05% + 500 mV
Current
(3)
0.1% + 8.5 mA 0.1% + 5 mA
General
Transient Response Time
(4)
≤0.5 ms ≤0.5 ms
OVP adjustment Range 5 - 660 V 5 - 1100 V
OVP Accuracy 6 V 10 V
OCP Accuracy 85 mA 50 mA
Command Response Time 20 ms 20 ms
Efficiency
(5)
90% 90%
Power Factor 0.99 0.99
Remote Sense Compensation 6 V 10 V
Rising Time at Full Load ≤100 ms ≤250 ms
Rising Time at No Load ≤100 ms ≤250 ms
Falling Time at Full Load ≤100 mS ≤150 ms ≤250 ms
Falling Time at No Load ≤3000 ms ≤5000 ms
Standard Interfaces Analog Programming, USB, RS485, RS232, GPIB, and Ethernet
AC Input
(6)
170 - 265 VAC single phase
Rated Frequency 47 - 63 Hz
Maximum Rated Input Power 5800 VA 3500 VA 5800 VA
Temperature Ratings
Operation (0 °C~40 °C)
Storage (-40 °C~85 °C)
Dimensions ( W× H× D ) 16.53” x 3.46” x 20.94” (420 x 88 x 532 mm)
Weight 32.18 lbs (14.6 kg)
Three-Year Warranty
Standard Accessories User manual, power cord, test report & certificate of calibration
Optional Accessories SASPVS (SAS software), RKPVS (rackmount kit)
(1)
Minimum voltage is guaranteed to 5V.
(2)
Minimum current is guaranteed to maximum 0.4% of rated output current.
(3)
Current accuracy is applied when output power > 0.1% of full power.
(4)
Time for output voltage to recover within 0.5% of its rated output for a load change 50 – 100% of rated output current.
(5)
90% typical at nominal line and max load.
(6)
10% of output de-rated when operating below 190 VAC.
Specifications