Datasheet

v042516
6 www.bkprecision.com
High Power Programmable DC Power Supplies
PVS Series
Model PVS60085 PVS60085MR PVS10005
Output Rating
Output Voltage
(1)
0 - 600 V 0 - 1000 V
Output Current
(2)
0 - 8.5 A 0 - 5 A
Max. Output Power 5100 W 3000 W 5000 W
Line Regulation
Voltage 60 mV 100 mV
Current 4.25 mA 2.5 mA
Load Regulation
Voltage 60 mV 100 mV
Current 8.5 mA 5 mA
Ripple and Noise (20 Hz - 20 MHz)
Voltage 100 mVrms / 500 mVpp 100 mVrms / 600 mVpp
Current 15 mA 10 mA
Resolution
Programming 10 mV/0.2 mA 0.1 V/0.1 mA
Readback 10 mV/0.2 mA 0.1 V/0.1 mA
Programming Accuracy
Voltage 400 mV 700 mV
Current
(3)
± (%output + offset) 0.03% + 3.5 mA 0.03% + 2 mA
Readback Accuracy ± (%output + offset)
Voltage 0.05% + 300 mV 0.05% + 500 mV
Current
(3)
0.1% + 8.5 mA 0.1% + 5 mA
General
Transient Response Time
(4)
0.5 ms 0.5 ms
OVP adjustment Range 5 - 660 V 5 - 1100 V
OVP Accuracy 6 V 10 V
OCP Accuracy 85 mA 50 mA
Command Response Time 20 ms 20 ms
Efficiency
(5)
90% 90%
Power Factor 0.99 0.99
Remote Sense Compensation 6 V 10 V
Rising Time at Full Load 100 ms 250 ms
Rising Time at No Load 100 ms 250 ms
Falling Time at Full Load 100 mS 150 ms 250 ms
Falling Time at No Load 3000 ms 5000 ms
Standard Interfaces Analog Programming, USB, RS485, RS232, GPIB, and Ethernet
AC Input
(6)
170 - 265 VAC single phase
Rated Frequency 47 - 63 Hz
Maximum Rated Input Power 5800 VA 3500 VA 5800 VA
Temperature Ratings
Operation (0 °C~40 °C)
Storage (-40 °C~85 °C)
Dimensions ( W× H× D ) 16.53” x 3.46” x 20.94” (420 x 88 x 532 mm)
Weight 32.18 lbs (14.6 kg)
Three-Year Warranty
Standard Accessories User manual, power cord, test report & certificate of calibration
Optional Accessories SASPVS (SAS software), RKPVS (rackmount kit)
(1)
Minimum voltage is guaranteed to 5V.
(2)
Minimum current is guaranteed to maximum 0.4% of rated output current.
(3)
Current accuracy is applied when output power > 0.1% of full power.
(4)
Time for output voltage to recover within 0.5% of its rated output for a load change 50 – 100% of rated output current.
(5)
90% typical at nominal line and max load.
(6)
10% of output de-rated when operating below 190 VAC.
Specifications