Datasheet

www.bkprecision.com
High Power Programmable DC Power Supplies
PVS Series
4
Extensive device protection
To protect your DUT, the PVS Series provides several safety features: over-
voltage (OVP), overcurrent (OCP), overpower (OPP), and overtemperature
(OTP) protection. When a fault occurs, the power supply will turn off the
output, sound an alarm, and display an error message. Similarly, with constant
voltage-to-constant current (CV-to-CC) or constant current-to-constant
voltage (CC-to-CV) foldback protection mode activated, the supply will shut
down if load changes force the supply to transition between the two operating
modes. The power supply is also able to detect abnormally low or high AC
input power and turn the output off when this condition occurs.
Master/Slave operation
Models with the same rating can be connected in parallel and operate in
master/slave mode. The RS-485 interface is used for communication between
the master and slave(s). Once configured, the master will automatically search
for and detect slave units, and display the voltage and current of the complete
system.
In multi-unit control mode, multiple units can be daisy chained via RS485 and
controlled from one master unit through the USB, GPIB, or LAN interface.
Multi-unit control
Flexible configuration
Using a 5 ½ digit multimeter, voltage and current parameters can be
conveniently calibrated from the front panel via the calibration menu.
Convenient front panel guided calibration
AC input power cord (Standard)
Rackmount kit (Optional)