User Manual

2.
Press
button one time until
PROTECT
is select and press
. The display will then show
OVP.
3.
Press
button one time until OCP is displayed,
and press
.
4.
Use numerical keys directly or use
keys with rotary
adjustment followed by
to
confirm the OCP value.
5.
Press
several times to exit the menu setting.
When OCP protection is tripped during operation, the output will turn off and the following OCP status
message will display:
To clear the trip status, press
once.
3.4.3
Configure Over Power Protection (OPP)
The MR overpower protection continuously monitors the output power
level. If it is greater than
the OPP setting, it turns off the power supply output to protect the device under test.
Follow the steps below to set the OPP limit:
1.
Press
button
,
select
CONFIGURATION
, then press
.
2.
Press
button one time until
PROTECT
is select and press
. The display will then show
OVP.
3.
Press
button two times until OPP is displayed,
and press
.
4.
Use numerical keys directly or use
keys with rotary
adjustment followed by
to
confirm the OPP value.
5.
Press
several times to exit the menu setting.
When OPP protection is tripped during operation, the output will turn off and the following OPP status
message will display: