User Manual

PFC ERROR !
PFC not functioning correctly
POWER OFF !
Power supply is powering off
OUTPUT SHORT CIRCUIT
Output voltage drop too fast
HW Fail BVbus
Module hardware fail
3.4 CONFIG Menu
All setup procedures and settings explained in this section can be
accessed from the
CONFIGURATION
menu. To access this menu, press
,
select
CONFIGURATION
, then
press
.
3.4.1 Output Limit Settings
The voltage or current output limits can be configured to provide limit
protection to prevent accidental
changes to the output settings. There are four limit values that can be set: voltage maximum
(VMAX), voltage
minimum (VMIN), current maximum (IMAX), and current minimum (IMIN).
Figure 3.2
Output Limit Settings Graph
Note: At any time during operation, when you are unable to set
to a desired voltage or
current, check these limit settings to
make sure the set value is within the limit’s range.
The shaded area illustrated above is the settable range of the output
voltage and current.
Follow the steps below to configure the output limits:
1
From the
CONFIGURATION
menu, select
LIMIT
, then press
. The following screen will
display: