Owner manual
66
Command Syntax
[SOURce:]POWer:CONFig[:LEVel] <NRf+>
Parameters
0 through max. Rated power
Unit
W (power)
Examples
POW:CONFig 100
Query Syntax
[SOURce:]POWer:CONFig[:LEVel
Returned Parameters
<NR3>
Related Commands
POW:PROT
[SOURce:]IMPedance
Channel Specific
This command sets the resistance value when in CZ mode.
Command Syntax
[SOURce:]IMPedance[:LEVel][:IMMediate] <NRf+>
Parameters
0 to 7500 ohms.
Unit
R (ohms)
*RST Value
MAXimum
Examples
IMP 5 IMP:LEV 3.5
Query Syntax
[SOURce:]IMPedance[:LEVel][:IMMediate]?
Returned Parameters
<NR3>
Related Commands
IMP:RANG
[SOURce:]IMPedance:RANGe
Channel Specific
This command is used to set the resistance range when the load is in CZ mode. This limits the settable
resistance.
Command Syntax
[SOURce:]IMPedance:RANGe <NRf+>
Parameters
0 to 7500 ohms.
Unit
R (ohms)
Examples
IMP:RANG 15 SOUR:IMP:RANGE MIN
Query Syntax
[SOURce:]IMPedance:RANGe?
Returned Parameters
<NR3>
[SOURce:]IMPedance:RESistance
Channel Specific