Owner manual
53
Command Syntax
[SOURce:]CURRent:RANGe <NRf+>
Parameters
0 through max. Rated current
Unit
A (amps)
*RST Value
max. current (high range)
Examples
SOUR:CURR:RANGE 5
Query Syntax
[SOURce:]CURRent:RANGe
Returned Parameters
<NR3>
Related Commands
CURR CURR:SLEW
[SOURce:]CURRent:SLEW
Channel Specific
This command sets the slew rate for all programmed changes in the input current level of the
electronic load. This command programs both positive and negative slew rates. MAXimum sets the
slew to the fastest possible rate. MINimum sets the slew to the slowest rate.
Command Syntax
[SOURce:]CURRent:SLEW[:BOTH] <NRf+>
Parameters
See specifications
Unit
A (amps per micro second)
Examples
CURR:SLEW MAX
Related Commands
CURR CURR:NEG CURR:SLEW:POS
[SOURce:]CURRent:SLEW:POSitive
Channel Specific
This command sets the slew rate of the current for positive transitions. MAXimum sets the slew to the
fastest possible rate. MINimum sets the slew to the slowest rate.
Command Syntax
[SOURce:]CURRent:SLEW:POSitive <NRf+>
Parameters
See specifications
Unit
A (amps per micro second)
Examples
CURR:SLEW:POS 0.0001
Query Syntax
[SOURce:]CURRent:SLEW:POSitive?
Returned Parameters
<NR3>
Related Commands
CURR:SLEW