Owner manual
50
Query Syntax
[SOURce:]REMote:SENSe[:STATe]?
Returned Parameters
<CRD>
[SOURce:]FUNCtion
Channel Specific
This command selects the input regulation mode of the electronic load.
CURRent constant current mode
RESistance constant resistance mode
VOLTage constant voltage mode
POWer constant power mode
IMPEDANCE constant impedance mode
Command Syntax
[SOURce:] FUNCtion <function>
Parameters
CURRent | RESistance | VOLTage | POWer | IMPEDANCE
*RST Value
CURRent
Examples
FUNC RES
Query Syntax
[SOURce:]FUNCtion?
Returned Parameters
<CRD>
[SOURce:]FUNCtion:MODE
Channel Specific
This command determines whether the input regulation mode is controlled by values in a list or by the
FUNCtion command setting.
FIXed The regulation mode is determined by the FUNCtion or MODE command.
LIST The regulation mode is determined by the active list.
Command Syntax
[SOURce:]FUNCtion:MODE <mode>
Parameters
FIXed | LIST
*RST Value
FIXed
Examples
FUNC:MODE FIX
Query Syntax
[SOURce:]FUNCtion:MODE?
Returned Parameters
<CRD>
Related Commands
FUNC
[SOURce:]TRANsient